Clearances
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
fireplace and flue system be installed only in accordance with these instructions.
Note: ACC40LE shown in illustration. Clearances will be the same for the ACC40RE.
Clearance: single sided
A: Mantel Height (min.)
B: Opening Height
C: From Floor
D: Sidewall (on one side)
E: Mantel Depth (Max.)
F: Alcove Depth
G: Convection Air Outlet
H: Convection Air Outlet Opening Offset
I: Chase Enclosure (Min.)
Clearance to sprinkler head
K:
Hearth
See mantel clearances chart in this manual.
**
I
D
Dimension
**
382mm
Min. 0mm
Min. 914mm
**
Min. 914mm
*
0-76mm
1600mm
914mm
(Min.)
0mm
F
H
G
E
A
B
C
F
CC40 UNIT
Measured From:
Top of Fireplace Opening
Bottom/Top of Fireplace Opening
Bottom of Fireplace Opening
Side of Fireplace Opening
Front of Fireplace Opening
Front of Fireplace Opening
Top of Enclosure
Max. offset from top of chase enclosure
From Base of Unit
Perpendicular from chase grill
No hearth required
D
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and flue
Top View
system be installed only in accordance with these instructions.
Alcove
Flue Clearances to Combustibles
Horizontal - Top
Horizontal - Side
Horizontal - Bottom
Vertical
Passing through wall/
floor/ceiling - when
firestop is used.
*
A minimum of 774 square centimetres of
open area, not lower than 76mm from top
of enclosure, required for all installations
Chase grill
The HeatWave Duct Kit has differ-
ent clearance and framing require-
ments, check the HeatWave manual
for details.
Caution Requirements
WARNING
Fire hazard is an extreme risk
City Series ACC40E |

installation

76mm
51mm
51mm
51mm
38mm
Sprinkler
K
L
Side view
23