Horizontal Terminations - Regency ACC40LENG Owners & Installation Manual

Zero clearance direct flue gas fireplace, city series
Hide thumbs Also See for ACC40LENG:
Table of Contents

Advertisement

installation

Horizontal Terminations

Flex Flue 102mm x 175mm
These venting systems, in combination with the ACC40LE/ACC40RE Direct Flue Gas Fireplace, have been tested and listed as a direct flue heater system
by Warnock Hersey/ Intertek. The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram in "Exterior Flue
Termination Locations" section.
Regency
Direct Flue (Flex) System Termination Kits includes all the parts needed to install the ACC40LE/ACC40RE using a flexible flue.
®
FPI Kit #
Length
Contains:
#946-515
1.2m
1.
2.
3.
4.
5.
6.
#946-516
3m
7.
8.
9.
Notes:
1. Liner sections should be continuous without any joints
or seams.
2. Only Flex pipe purchased from Regency
for Flex installations
3. Horizontal vent must be supported every 0.9m.
4. Regency
Direct Vent System (Flex) is only approved for
®
horizontal terminations.
5. Flex system can only be used up to a maximum continu-
ous vent length of up to 3m. If longer runs are required,
rigid pipe must be used.
| City Series ACC40E
40
175mm flexible outer liner (Kit length)
102mm flexible inner liner (Kit length)
spring spacers
thimble
AstroCap termination cap
screws
tube of Mill Pac
plated screws
S.S. screws #8 x 38mm drill point
may be used
®
102mm
Vent Guard - if required*
(Part #946-506/P)