installation
Horizontal Terminations
Rigid Pipe 102mm x 175mm
The minimum components required for a basic horizontal
termination are:
1
Horizontal Termination Cap
1
Rigid Pipe Adaptor (510-994)
1
Wall Thimble
1
Length of pipe to suit wall thickness
(see chart)
Wall thickness is measured from the back standoffs to the inside
mounting surface of termination cap. For siding other than vinyl
furring strips may be used instead of the vinyl siding standoff, to
create a level surface to mount the flue terminal. The Terminal
must not be recessed into siding. Measure the wall thickness
including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl
siding), measure to outside surface of wall without siding and
add 51mm.
Flat Wall Installation
Wall Thickness
(mm)
102mm-140mm
178mm-216mm
254mm-292mm
229mm-368mm
381mm-597mm
WARNING:
Do not combine venting components from
different venting systems.
Use of the the AstroCap
and FPI Riser is
TM
acceptable with all systems.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Flue, Selkirk Direct-Temp,
Ameri Flue Direct Venting, ICC Excel Direct,
Olympia Chimney and Security Secure Flue
systems. Use of these systems with the Rigid
Pipe adaptor is deemed acceptable and does
not affect the Intertek WHI listing of components.
The FPI AstroCap
TM
and FPI Riser Flue terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent
Metal Products Ameri Flue Direct Flue, Security Secure Vent
mark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Flue are registered and/or proprietary trademarks of Simpson Dura-Flue Co. Inc.
| City Series ACC40E
42
Vent Length Required
(mm)
152mm
229mm
305mm
279mm-371mm Adj. Pipe
432mm-610mm Adj. Pipe
, ICC Excel, Selkirk Direct-Temp and Olympia Chimney. AstroCap
®
Vinyl Siding
Standoff (Optional)
Adj.Pipe Length
90 Elbow
o
Pipe Length
Rigid Pipe Adapter
When using Rigid Flue other than
Simpson Dura-Flue, 3 screws must be
used to secure rigid pipe to adaptor.
Horizontal
Termination Cap
Wall Thimble
®
Direct Flue, American
is a proprietary trade-
TM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acc40lelpAcc40leulpgAcc40rengAcc40relpAcc40reulpg