Copy of Data Badge
Gas Type
Model
Gas Consumption High
Gas Consumption Low
Supply Pressure (Min.)
Manifold Pressure High
Manifold Pressure Low
Injector Size
Approval No. GMK10594
AS/NZS 5263.0 & AS/NZS 5263.1.8
Electrical: 240V
920-216
920-123e
Part #: 920-123e
Colour: Black on Grey
Size: 100% 7" W x 2.7" H
June11/19: Created decal
June 13/19: Removed -11 as per Daniela
DO NOT OPERATE THIS APPLIANCE BEFORE READING THE
Jan. 28/20: Added approval number.
INSTRUCTIONS BOOKLET.
DO NOT PLACE ARTICLES ON OR AGAINST THIS
Feb. 12/20: Removed first "injector size" value, updated "gas consumption low"
APPLIANCE
Feb. 19/20: Added label "Primarily a decorative and not a heating appliance"
DO NOT STORE CHEMICALS OR FLAMMABLE MATERIALS
NEAR THIS APPLIANCE.
Mar. 2/20: Changed some consumption and pressure values.
DO NOT OPERATE WITH PANELS, COVERS OR GUARDS
REMOVED FROM THIS APPLIANCE .
Part #: 908-602c
Colour: Black on White, expect what is indicated in yellow.
Size:
printed at 100%
July 18/17: Rev. C - Changed wording on Line 3 as per AGA -
removed Lines 4, 6 and 7 - updated caution
symbol size and font size to 10pt
May 7/14: Changed wording on Line 3 as per AGA
Dec 12/12: Removed redundant 'do not' from the last line
| City Series ACC40E
4
Mar. 3/09: Rev. A - added information
Nov. 6/06: no changes to artwork.
Regency Gas Fireplace
NG
Propane
ACC40LENG
ACC40LELP
ACC40RENG
ACC40RELP
30 MJ/h
17.1 MJ/h
16.0 MJ/h
1.13 kPa
0.96 kPa
0.30 kPa
2.40 mm
PRIMARILY A DECORATIVE AND NOT A
50/60 Hz
HEATING APPLIANCE
ULPG
ACC40LEULPG
ACC40REULPG
30 MJ/h
24 MJ/h
11.7 MJ/h
2.75 kPa
2.75 kPa
2.60 kPa
2.60 kPa
0.70 kPa
0.63 kPa
1 x #53
1 x #54
1.51 mm
1.39 mm
908-602c
Distributed by:
Western Australia:
Air Group Australia
28 Division St
Welshpool, WA 6106
Eastern Australia
Fireplace Products
Australia Pty. Ltd.
1 Conquest Way
Hallam, VIC 3803
New Zealand
Aber Holdings
17 Main Street Place
Te Rapa, HA 3200
To be installed by an authorised person in
accordance with installation instructions
provided with the appliance.
528
Serial
Number