Operating Weights - Copper Fin Coils - York MILLENNIUM YCAS Installation Operation & Maintenance

Air-cooled screw liquid chiller
Table of Contents

Advertisement

Technical Data
OPERATING WEIGHTS – COPPER FIN COILS
YCAS
A
B
C
D
0373 764
691
861
––
0403 777
700
880
––
0453 782
708
883
––
0503 794
717
901
––
0543 796
633
784
589
0573 803
640
794
591
0623 814
646
803
599
0653 901
732
1060
499
MAX LOAD
ISOLATOR
TYPE & SIZE
lbs.
AWMR-1-53
1000
AWMR-1-530
1150
AWMR-1-531
1276
AWMR-1-532
1500
AWMR-1-551
1676
AWMR-1-552
1900
AWMR-1-553
2200
AWMR-2-531
2552
AWMR-2-532
3000
INSTALLATION INSTRUCTIONS FOR VMC SERIES AWR/AWMR
1. Floor should be level and smooth.
2. For indoor applications, isolators do not normally
require bolting. If necessary, anchor isolators to floor
through bolt holes in base plate. IMPORTANT:
Isolators must be bolted to substructure and
equipment to isolators when used under out-
door equipment exposed to wind forces.
3. Lubricate threads of adjusting bolt. Loosen hold-
down bolts to allow for isolator adjustment.
4. Block the equipment 1/4" higher than the specified
free height of the isolator. To use the isolator as
blocking for the equipment, insert a 1/4" shim be-
tween the upper load plate and vertical uprights.
Lower the equipment on the blocking or shimmed
isolators.
78
COPPER FIN COIL WEIGHT DISTRIBUTION BY MODEL ( KGS )
E
F
G
H
607
745
899
––
627
757
928
––
614
754
908
––
633
767
937
––
877
615
754
697
867
612
748
689
884
621
762
702
960
681
1147
514
DEFL.
kg
in.
mm
453.6
2
51
521.6
2
51
578.8
2
51
680.4
2
51
760.2
2
51
861.8
2
51
997.9
2
51
1157.6
2
51
1360.8
2
51
AND CP RESTRAINED MOUNTINGS
I
J
K
L
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
MAX LOAD
ISOLATOR
TYPE & SIZE
lbs.
kg
CP-2-26
1200
544.3
CP-2-27
1500
680.4
CP-2-28
1800
816.4
CP-2-31
2200
997.9
CP-2-32
2600
1179.3
CP-2-35
3000
1360.8
5. Complete piping and fill equipment with water, re-
frigerant, etc.
6. Turn leveling bolt of first isolator four full revolu-
tions and proceed to mount each in turn.
7. Continue turning leveling bolts until equipment is fully
supported by all mountings and equipment is raised
free of the spacer blocks or shims. Remove blocks
or shims.
8. Turn leveling bolt of all mountings in either direction
in order to level the installation.
9. Tighten nuts on hold down bolts to permit a clear-
ance of 1/8" between resilient washer and under-
side of channel cap plate.
10. Installation is now complete.
M
N
O
P
TOTAL
––
––
––
––
4,567
––
––
––
––
4,668
––
––
––
––
4,649
––
––
––
––
4,750
––
––
––
––
5,745
––
––
––
––
5,744
––
––
––
––
5,831
––
––
––
––
6,494
DEFL.
SPRING
COLOR
in.
mm
1.17
29.7
Purple
1.06
26.9
Orange
1.02
25.9
Green
0.83
21.0
Gray
0.74
18.7
White
0.70
17.7
Gold
YORK INTERNATIONAL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents