Configuring Basic Parameters; Accessing The Monitor Program - Alvarion BreezeACCESS II CX System Manual

Cell extender
Hide thumbs Also See for BreezeACCESS II CX:
Table of Contents

Advertisement

Chapter 3 - Commissioning

Configuring Basic Parameters

After completing the installation process, as described in the preceding
chapter, the basic parameters must be configured to ensure that the
unit operates correctly. Once the basic parameters have been
configured, additional parameters can be remotely configured via the
Ethernet port or the wireless link using Telnet or SNMP management, or
by loading a configuration file.
Local configuration of parameters can be performed using any of the
following methods:
Accessing the Monitor program via the Monitor port – applicable
only to 900 MHz and 2.4 GHz units.
Accessing the Monitor program via Telnet.
Using the BreezeCONFIG utility for the applicable product line
(BreezeCONFIG ACCESS for 900 MHz and 2.4 GHz units,
BreezeCONFIG for BreezeACCESS VL for BreezeACCESS VL units)

Accessing the Monitor Program

To access the Monitor Program using the Monitor cable (900 MHz and
2.4 GHz units):
To configure 900 MHz and 2.4 GHz units, use the special Monitor cable
supplied with the Cell Extender to connect the Ethernet connector of
the unit to the COM port of a PC running a terminal emulation
program.
The Dual Monitor cable supplied with equipment where both AU and SU
have a Monitor port (CX-BA2.4-BA2.4, CX-BA2.4-BA900) have two 9-
pin D-type plugs. One plug connects to the SU interface module inside
the unit and the other plug connects to the AU module.
The Special Monitor cable supplied with equipment where only the AU
has a Monitor port (2.4 GHz or 900 MHz AU) has one 9-pin D-type plug
that connects to the AU interface module inside the unit.
1. Run a terminal emulation program, such as HyperTerminal™.
2. Set the communication parameters as shown in Table 3-1.
3. Press Enter. The Select Access Level menu is displayed.
3-2
Cell Extender System Manual

Advertisement

Table of Contents
loading

Table of Contents