Audio Setting - Sony HXCU-FB70 Service Manual

With fiber connector kit hkc-lc02
Hide thumbs Also See for HXCU-FB70:
Table of Contents

Advertisement

Intercom Signal Flow
INTERCOM/TALLY/
PGM connector
Producer line
!'
X
Talk
Y !,
X !]
Receive
Y !\
G !;
Engineer line
X 4
Talk
Y 5
X 1
Receive
Y 2
G 3
6
X
Program line
7
Y
8
G
3-2-2.

Audio Setting

This unit can receive two independent microphone lines (Audio1, Audio2) from the camera and output them.
Note
Set the intercom system with CCU CONFIGURATION menu. (Refer to the Operating Instructions.)
Remote Controlling audio input gain
Remote Control Using the CCU CONFIGURATION Menu
Set the gain with C05: MIC/AUDIO of the CCU CONFIGURATION menu.
20, 30, 40, 50, 60 dB (factory setting: 60 dB)
Control from the RCP-1500 series
Remote control can be set from the Maintenance menu of the RCP-1500 series connected to this unit .
20, 30, 40, 50, 60 dB
Note
Maintenance menu → Camera → Microphone Gain
Setting Audio Output Level
Set the Audio outputs (CH-1 and CH-2) with C05: MIC/AUDIO according to each signal level.
-20 dB, 0, or +4 dB (factory setting: 0 dB)
HXCU-FB70
CCU menu
C06: SYSTEM I/F
PROD
4W/RTS (CC)
ENG
4W/RTS (CC)
CCU menu
C06: PGM1 LEVEL
-20/0/+4dBu
ENG/PROD
switch
CCU menu
C07: PGM LEVEL
Front panel
INTERCOM connector
PROD
ENG
PGM
3-6