3-1-5. Initial Setting

1. Initial setting of each switch
CCU-700/700P
[VA-156 board]
S1 (Y SEL CAM/AUX)
S125 (R-Y SEL CAM/AUX)
S126 (TEST ON/OFF)
S221 (B-Y SEL CAM/AUX)
S1892 (V BLKG); NTSC ONLY
S1962 (REMOTE REM/LOCAL)
S2032 (CB SELECT) [For UC]
[For EK]
[DM-94 board]
S1 (MODE AUTO/MANU)
S3 (Y 2nd AGC)
S4 (C 2nd AGC)
[AT-88 board]
S201 (MIC 1 GAIN 0dB/–20dB)
S301 (MIC 2 GAIN 0dB/–20dB)
S1006 (REMOTE MODE 1 CMD/ISR)
S1007 (REMOTE MODE 2 CMD/ISR)
S2061 (INPUT SELECT 1CH/2CH)
S2081 (PGM GAIN 0dB/–20dB)
S2082 (PGM MIX ON/OFF)
S2341 (INCOM MIX ON/OFF)
*1: When finishing the adjustment, set S126 (TEST ON/
OFF)/VA-156 board to "OFF".
*2: S1962 is set to "REMOTE" at the factory.
*3: When finishing the adjustment, set S2032 (CB SE-
LECT)/VA-156 board to your desired position.
CCU-700A
CCU-700AP
MSU-700
• POWER AND SIGNAL SWITCH BLOCK
ALL button
CAM PW button
TEST 1 button
TEST 2 button
Marked side
BARS button
Marked side
CLOSE button
"ON" *1
• CAMERA HEAD/CCU CIRCUIT ON/OFF BLOCK
Marked side
"20H"
DETAIL OFF button
"LOCAL" *2
KNEE OFF button
"SMPTE" *3
AUTO KNEE button
"EBU"*3
MATRIX OFF button
• AUTO SETUP BLOCK
"AUTO"
LEVEL button
"ON"
WHITE button
"ON"
BLACK button
• OTHERS
"0dB"
GAMMA OFF button
"0dB"
MASTER GAIN select button
"CMD"
2. Presetting of compensation signal
"CMD"
"2CH"
"0dB"
• Preset (center value) all compensation signals output
"OFF"
from the microcessor before starting the adjustment. If
"ON"
not, the adjustments will not be set correctly even if the
specifications are met.
• How to preset the compensation data.
1 Turn off the power of CCU.
2 S1002-8 (CONTROL CLEAR)/AT-88 board → "ON"
3 Turn on the power of CCU.
n
• This switch setting is valid only when the CCU
number set with S1001/AT-88 board is 96 or less.
• When the switches 1to 8 of S1001/AT-88 board are all
set to "ON" with S1002-8 set to "ON", the data of
hour meter stored in microprocessor on the AT-88
board is reset.
• When the switches 2 to 8 of S1001 are set to "ON"
with S1002-8 set to "ON", the special character signal,
set by a customer, is deleted.
• When finishing the overall adjustment, set S1002-8
(CONTROL CLEAR) /AT-88 board to "OFF".
3-1. Preparation
"OFF (lamp goes off)"
"ON (light up)"
"OFF (lamp goes off)"
"OFF (lamp goes off)"
"OFF (lamp goes off)"
"ON (light up)"
"OFF (light up)"
"OFF (light up)"
"OFF (lamp goes off)"
"OFF (light up)"
"OFF (lamp goes off)"
"OFF (lamp goes off)"
"OFF (lamp goes off)"
"ON (lamp goes off)"
"0"
3-3