CP PM faceplates LEDs

There are two LEDs on CP PM faceplate:
Status LED
Redundancy LED

System alarms

Major and minor alarms can be displayed on the attendant console
when connected to the system. However, attendant consoles cannot
be connected to an MG 1000T and therefore cannot display MG 1000T
alarms.
Major alarms
A major alarm indicates a fault that seriously interferes with call
processing. The causes of major alarms are listed in
major and minor alarms" (page
When an MG 1000E is equipped with a power fail transfer unit (PFTU),
a major alarm causes designated analog (500/2500-type) telephones to
connect directly to Central Office trunks. This is called a line transfer.
Minor alarms
A minor alarm indicates that the system hardware or software has detected
a fault requiring attention. The causes of minor alarms are listed in
14 "Causes of major and minor alarms" (page
A minor alarm is indicated on attendant consoles in customer groups
affected by the fault. A minor alarm indication on the console is an
optional feature, enabled and disabled on a customer basis through data
administration procedures.
Red indicates the power-up (by H/W) is on
Yellow indicates that the OS is loaded (by S/W)
Green indicates that "appstart" completed for software
Red indicates boot up (by HW) is on.
Blank indicates when the OS starts (by S/W)
Nortel Communication Server 1000
Communication Server 1000E Maintenance
NN43041-700 04.01 4 June 2010
Copyright © 2004-2010 Nortel Networks. All Rights Reserved.
54).
54).
System alarms 53
Table 14 "Causes of
Table

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs 1000e

Table of Contents