Chassis Status Leds - Alcatel-Lucent OmniSwitch 6900 Hardware User's Manual

Hide thumbs Also See for OmniSwitch 6900:
Table of Contents

Advertisement

OmniSwitch 6900 Chassis

Chassis Status LEDs

The chassis provides a series of status LEDs offering basic status information for hardware operation and
port link and activity status.
LED
OK
PS
OK and PS (Together)
GRN
EMP
Port LEDs*
*For OS6900-Q32 and OS6900-X72 port status LEDs, refer to
page 3-24
State
Solid Green
Blinking Green
Blinking Amber
Solid Green
Solid Amber
Blinking Amber/Green
Blinking Amber
Blinking Green
Solid Green
Blinking Green
Solid Green
Blinking Green
Chassis and Power Supplies
Description
Operational; if the switch is part of a Virtual
Chassis (VC), it is operating in slave mode.
This switch is functioning as the master
chassis within a VC.
In transitional state (e.g. performing
diagnostics or booting)
Both power supplies are functional
One power supply is functional
The switch is missing a fan tray, or a bootup
has been attempted with a power supply and
fan tray that have mismatched airflow
directions. (The GRN power save LED also
blinks green. See information below.)
The switch is missing a fan tray, or a hot swap
has been attempted with a power supply and
fan tray that have mismatched airflow
directions. The GRN power save LED
(described below) also blinks green. For
detailed information on airflow mismatch, see
page
3-35.
The GRN power save feature is not supported
on the OmniSwitch 6900. For OS6900
switches, this LED is used (in addition to the
OK and PS LEDs) to indicate an airflow
direction error between the power supplies and
fan tray, or a missing fan tray. For detailed
information on airflow mismatch, see
page
3-35.
EMP port link is up
EMP port link is active
Valid link
Port is active
page
3-26.