Husqvarna Automower 305 Technical Manual page 28

Hide thumbs Also See for Automower 305:
Table of Contents

Advertisement

User interface (5-3-2)
Keypad (5-3-2-1)
The display indicates which button is pressed down.
Press Arrow back to exit the test.
Display (5-3-2-2)
The display flashes on and off a number of times.
Press any key to exit the test.
Sound (5-3-2-3)
Place the cursor on Sound and press OK. The
buzzer then emits a short sound signal at the same
time as a note is shown in the display.
Press Arrow back to exit the test.
Charging station (5-3-3)
This function is used to quickly check that there
is a signal at A, F and Guide. The test also shows
whether the mower is receiving a charge from the
charging station.
Place the mower in the charging station and start the
test by pressing OK.
NOTE! The robotic lawnmower must be synchronised
with the charging station to be able to conduct the
test. Use the New loop signal function in the Security
menu to synchronise.
The result of the test is OK if the conditions in the
table below are fulfilled.
Table 17: Test conditions charging station
Test
A loop
Guide wire
F loop
Charging voltage
To carry out a thorough inspection of the signal
strength and the charge current, it is recommended
to use Battery (5-1-2) and Loop (5-1-3).
English - 26
2. SPECIAL MENU FUNCTIONS
Value OK
> 50
> 50
-100 to -300
> 15 V
2.8.4 Special settings (5-4)
The sub-menu consists of two part menus which
giver access to specialised settings.
Info
History
Test
Special settings
Loop signal (5-4-1)
This function makes it possible to temporarily switch
off a mower's loop detection, i.e. the mower can be
run without the installed the charging station and
boundary wire. One such occasion can for instance
be a demonstration of a robotic lawnmower at the
home of a customer.
This sub-menu offers two options, where Normal is
the normal operation mode.
Normal
Override
The function is automatically set to Normal when the
mower is turned off and on using the main switch.
Calibrate tilt sensor (5-4-2)
To calibrate, i.e. reset the tilt sensor: Place the
robotic lawnmower on a horizontal surface. Move the
cursor to Calibrate tilt sensor and press OK.
Demo mode (5-4-3)
In demo mode the robotic lawnmower works without
starting the blade disc. The mower runs for 4 minutes
followed by a short charge.
The Demo mode is ideal for use in installations such
as in shops or exhibitions.
Loop signal
Calibrate tilt sensor
Demo mode

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Automower 308Gardena r40liGardena r70li

Table of Contents