Technical Specifications; Troubleshooting - Stihl RLE 540 Instruction Manual

Hide thumbs Also See for RLE 540:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 27
TÜV Rheinland LGA Products GmbH
Tillystraße 2
D-90431 Nürnberg
Compilation and storage of technical
documentation:
Sven Zimmermann
STIHL Tirol GmbH
The year of manufacture and machine
number appear on the rating plate of the
machine.
Measured sound power level:
86,0 dB(A)
Guaranteed sound power level:
89 dB(A)
Langkampfen,
2018-07-02 (YYYY-MM-DD)
STIHL Tirol GmbH
Head of Design

18. Technical specifications

Type
RLE 540.0
Serial number
6290
Motor, design
Electric motor
Voltage
230 V~
Power input
1600 W
0478 670 9906 A - EN
Type
RLE 540.0
Frequency
50 Hz
Fuse
10 A
Protection class
II
Type of protection
IPX 4
Scarifying device
14 fixed vertical
blades
Scarifying blade
drive
Permanent
Motor output speed
2840 rpm
Working width
38 cm
Working depth
6 levels, adjust-
ment range
25 mm
Wheel diameter
(front)
180 mm
Wheel diameter
(rear)
180 mm
Length
126 cm
Width
54 cm
Height
111 cm
Weight
28 kg
Sound emissions:
In accordance with Directive 2000/14/EC:
Guaranteed sound
power level L
89 dB(A)
WAd
In accordance with Directive 2006/42/EC:
Sound pressure level
at workplace L
72 dB(A)
pA
Uncertainty K
2 dB(A)
pA
Hand-arm vibrations:
Specified vibration characteristic in
accordance with EN 12096:
Measured value a
1,95 m/sec
hw
Uncertainty K
0,98 m/sec
hw
Measurement in accordance with
EN 20643

19. Troubleshooting

If necessary, contact a specialist
dealer; STIHL recommends STIHL
specialist dealers.
Fault:
Motor not starting
Possible cause:
– No mains voltage
– Scarifying unit not in transport position
– ON button not pressed
– Blade shaft blocked
– Electric cable/plug and plug connector
or switch defective
– Thermal motor overload protection
activated
Remedy:
– Check fuse (
– Place scarifying unit in transport
position (
7.3)
– Press ON button (
– Place scarifying unit in transport
position and clean housing and
discharge chute (disconnect mains
plug!) (
7.3), (
– Check cable/plug/switch and replace if
necessary (
10.1), ( )
– Allow machine to cool down (
( )
Fault:
Frequently tripped mains fuse
Possible cause:
2
– Unsuitable electric cable
2
– Power overload
– Machine overloaded due to working
with blades set too deep
Remedy:
– Use suitable electric cable (
10.1)
10.3)
11.2)
8.4),
10.1)
39