Datamax I-Class Mark II Operator's Manual page 39

Hide thumbs Also See for I-Class Mark II:
Table of Contents

Advertisement

Advanced Ent ry Calibrat ion ( cont inued)
St ep
Act ion
Press t he ESC Key.
Use t he but t ons t o scroll t o PAPER
SENSOR LEVEL ( or if using
reflect ive m edia, REFL PAPER
N
LEVEL) and t hen press ENTER.
Use t he but t ons t o set t he Paper
value det erm ined in St ep M and
t hen press ENTER.
Press t he ESC Key.
Scroll t o GAP SENSOR LEVEL ( or,
if using reflect ive m edia, MARK
SENSOR LEVEL) and t hen press
O
ENTER.
Set t he Gap ( or Mark) value
det er m ined in St ep M and t hen
press ENTER.
Press t he ESC Key.
Scroll t o EMPTY SENSOR LEVEL
P
and t hen press ENTER.
Set t he Em pt y value det erm ined in
St ep M and t hen press ENTER.
Press t he EXI T Key and, w hen
Q
prom pt ed, press YES at t he SAVE
CHANGES prom pt .
Ch a pt e r 3 - Pr int e r Ope r a t ion
Displayed Message
PAPER SENSOR LEVEL
( 0 - 255)
173
GAP SENSOR LEVEL
( 0 - 255)
042
EMPTY SENSOR LEVEL
( 0 - 255)
009
OFFLI NE
Com m ent
This is t he Paper value.
This is t he Gap ( or Mark) value.
This is t he Em pt y value.
The procedure is finished, t he
process alm ost com plet e.
3 3

Advertisement

Table of Contents
loading