Oki Data CONFIDENTIAL
4.2.7.11 Frame-OP-panel / OPE board (MC562/MC562dw)
(1) Remove the eight claws to remove the OPE board ① .
(2) Remove the LCD cable, while part A is raised in the direction of arrow.
Method of removing LCD cable
44952001TH Rev.2
LCD cable
Part A
(3) Remove the rubber-pad (R) ② and rubber-pad (L) ③ .
(4) Remove the button and lens ④ to ⑮ .
(5) Remove the cover bottom ⑯ and cover-cable ⑰ and LCD-assy ⑱ .
(6) Remove the eight latches to remove the cover-op-panel ⑲ .
(7) Remove the cover-KB-assy ⑳ .
(8) Remove the film-one-touch and sheet-one-touch .
8 × claws
ViewA
4.REPLACEMENT OF PARTS
8 × Latches
ViewA