2.1. Basic information on safety.................. 1 2.2. Symbols used ...................... 1 Inspection characteristics of the BENNING MA 3 ......1 Operating elements ................2 Connecting the BENNING MA 3 ............3 Testing with the BENNING MA 3 ............3 6.1.
The BENNING MA 3 measuring adapter helps you to test Please read the operating manual of the BENNING MA 3 and portable devices. Due to its robust design, it is particularly the operating manual of the appliance tester carefully and suited for being used in industrial environments.
BENNING MA 3 measuring adapter 4. Operating elements Meaning Pos. PE socket for PE test probe (for RPE cable test) CEE connector: 16 A, 50 Hz to 60 Hz, 380 V to 415 V, 3L+N+PE, 6h CEE connector: 16 A, 50 Hz to 60 Hz, 230 V,...
Connecting the BENNING MA 3 ble test samples”. Connecting the BENNING MA 3 to the appliance tester RPE – BENNING MA 3 (e. g. CEE 5-pin, 32 A) Setup for measuring the internal RPE resistance of the MA 3 Connection diagram...
Connect the CEE connector of the test sample to the Subtract the measured RPE value of the socket of the BENNING MA 3. BENNING MA 3 from the RPE measuring result of the Start the RInsu measurement on your appliance test sample. tester.
Page 8
BENNING MA 3 measuring adapter Application Class I; RInsu; LN to PE Class I; RInsu; LN to secondary Portable test sample Portable test sample Connection diagram Connection diagram Circuit diagram Circuit diagram Class I; RInsu; secondary to PE Class I; RInsu; LN to accessible conductive parts without PE...
BENNING MA 3 measuring adapter 6.1.3. Alternative leakage current measurements Class II; RInsu; LN to bodies The BENNING MA 3 can be used for measuring the fol- Portable test sample lowing leakage or fault currents by means of the alterna-...
Page 10
BENNING MA 3 measuring adapter Test procedure VDE 0701-0702 Test procedure VDE 0751-1 Class I; ICont – contact current Class I; ILeak – device leakage current Portable test sample Portable test sample Connect the CEE connector of the test sample to the ...
Page 11
BENNING MA 3 measuring adapter Test procedure VDE 0751-1 Test procedure VDE 0751-1 Class I; IPLeak – patient leakage current Class II; IPLeak – patient leakage current Portable test sample Portable test sample Connect the CEE connector of the test sample to the ...
BENNING MA 3 for future measurements and add them to the measuring adapter. RPE – BENNING MA 3 (e. g. CEE 5-pin, 32 A) Setup for measuring the internal RPE resistance of the MA 3 Connection diagram...
BENNING MA 3 to the be applied to CEE connecting cables and extension ca- locking position “L1-L2-L3”. bles. The BENNING MA 3 measuring adapter is Test procedure VDE 0701-0702 supplied with mains voltage. Class I; RInsu The functional test and phase sequence test of...
10. Warranty terms L1-L2 shorted The BENNING MA 3 measuring adapter is subject to strict quality control. In case of faults with regard to correct func- L2-L3 shorted tioning, we grant a manufacturer’s warranty of 24 months.