Sony HDC4300 Service Manual page 115

Hide thumbs Also See for HDC4300:
Table of Contents

Advertisement

3.
Adjust the waveform on the monitor so that the waveform levels out it as much as possible.
Adjustment item : H SAW
Adjustment item : H PARA
Adjustment item : V SAW
Adjustment item : V PARA
H: LINE
(H SAW)
V: FIELD
(V SAW)
4.
Make the same adjustment for channels G and B.
5.
Operate the control panel of MSU, and perform the automatic white balance adjustment.
WHITE button → ON (lit)
After the adjustment is completed, the message "AWB : OK" is displayed. OHB File Store
Store the OHB file in the MSU menu.
Store the OHB file in the MSU menu.
Procedure
1.
FILE button → ON (dark)
2.
Touch panel operation : [OHB File] → [OHB Store] → [Store]
When the store operation is completed, the message "OHB File Store" is displayed.
Adjustment for Lens Extender or Shrinker
When the WHITE or shading of V is out of alignment by using the lens extender or lens shrinker, perform the following
lens adjustment after storing the OHB file
Procedure
1.
Operate the control panel of MSU, and perform the automatic white balance adjustment.
WHITE button → ON (lit)
After the adjustment is completed, the message "AWB : OK" is displayed.
2.
Set the lens extender to ×1.
3.
Operate the control panel of MSU, and store the lens file.
(1) FILE button → ON (lit)
(2) Touch panel operation : [Lens File] → [Lens Store] → [Store]
HDC4300