3 Controller
(3) Automatic Operation/Jog Operation/Brake Release and Necessary Switch Settings
No
Operation
1
Jog operation
Jog operation
2
Note2)
Brake release
3
Note3)
Automatic
4
operation
Emergency stop input and output etc.
Related switch settings
Mode of
T/B
controller
enable/
enable switch
disable
Manual
Enable
Manual
Enable
Manual
Enable
Automatic
Disable
Note1)
T/B
Enabling
Door switch
device input
input terminal
terminal
ON
Close(ON)
ON
Open(OFF)
(Door Close)
ON
Close(ON)
(Door Close)
Description
If the enabling device input is set to
Close (On), the state of door switch
input does not matter.
If the enabling device input is set to
Close
Open (Off), door switch input must be
in a state of Close
Irrespective of the state of door
switch input, enabling device input
must be in a state of Close (On).
Close
Door switch input must always be in a
state of Close (Door Close).
CAUTION
-
-