3. Machine Initialization

3-1.How to initialize the terminal
Preparation:
Operation:
Date
00-00-00
Time
12:34 00
ID Character
MC #01
Date
Check System
Master
Time
Check cluster ID
0
ID Character
R/J/Order printer1
UP-350
Check System
R/J/Order printer2
UP-350
Check cluster ID
Slip Printer
SP-1300
R/J/Order Printer1
R/J/Order Printer2
Slip Printer
OK?
YES
OK?
Date
Time
ID Character
Check System
Check cluster ID
R/J/Order Printer1
R/J/Order Printer2
Slip Printer
OK?
Date
Time
ID Character
Check System
Check cluster ID
R/J/Order Printer1
R/J/Order Printer2
Slip Printer
OK?
1. All peripheral devices and terminals of this cluster should be
turned off.
2. Connect all of the peripheral devices (such as printer,
display etc.) to terminal.
3. Connect all terminals by in-line.
4. Turn on all peripheral devices of a terminal.
5. Turn on this terminal with pressing the Journal feed key and
release the key after the "Copyright" window is shown.
01-10-10
6. After releasing the key, enter "20000" (U.S.)/ "10000" (other
12:34 00
area: English), "40000" (other area: German), "50000" (other
MC #01
Master
area: French), "60000" (other area: Spanish) and press the
0
<ST> key.
UP-350
UP-350
SP-1300
YES
7. Enter the current date (YY/MM/DD order) and time and press
the <YES> key.
8. In ID character field, the auto-defined ID No. is shown.
We recommend that you should not change the value.
01-10-10
12:34 00
MC #01
Master
0
UP-350
UP-350
SP-1300
YES
9. In this field, you can select "1. Master/2. Backup Master/3.
Satellite/4. Selfmaster."
01-10-10
12:34 00
Please select one of these options and press the <YES> key.
MC #01
Master
0
UP-350
UP-350
SP-1300
YES