Introduction & Contents This manual is intended to be used as a reference to the TE-2200 and TE-2400 system. It provides details to allow whole understanding of the system capabilities, its operation, and how it can be used to solve many problems within the retail outlet.
Page 5
Scanning PLU ..........................131 Table analysis ..........................132 Grand total ............................. 132 General control ..........................132 Special character ........................... 132 Report header ..........................133 Tax table ............................133 Set menu table ..........................133 Batch X/Z ............................133 TE-2200/2400 Dealer's Manual...
Display Contrast control (Except for U.S. model) DATE/ HELP RECEIPT TIME ON/OFF LIGHT DARK CONTRAST Input/output connectors Input /output connectors COM ports are located in the leftside connector cover. SCANNER PC/MODEM COM2 COM1 TE-2200/2400 Dealer's Manual...
Peripheral ports and their connectable devices COM port Drawer Model Device port COM1 COM2 MODEM/PC External printer (Max. 2 printers) TE-2200 Slip printer TE-2400 Scanner Drawer 1 (Max 2) : can connect Available device/cable list External printer: UP-360 Printer cable:...
2. While holding down the <JOURNAL FEED>, turn the mode switch to PGM position. 3. Release <JOURNAL FEED> after the register shows “INIT”. 4. Enter “44449999” and press <SUBTOTAL>. 5. Enter “0” (communication speed: 38400 bps) and press <SUBTOTAL>. 6. Start the IPL program of the PC. COM1 port TE-2200/2400 Dealer's Manual...
IPL (Initial Program Loading) Via CF card (to send the IPL data to CF card) Operation 1. Set the mode switch to OFF position. 2. Open the CF card slot cover and insert the CF card securely. (Please check that the CF card is vacant. Refer to the “System utility section in PGM7”.) 3.
5. Enter 11-digit program code from the worksheet. 6. Press <SUBTOTAL> to register the program code. refer to Worksheet (Initialize) (Wait until beep twice.) 7. Press <SUBTOTAL> to register the program code. TE-2200/2400 Dealer's Manual...
Page 18
If error codes are printed on it, check the hardware and retry the operation. P01 03-04-2004 11:58 — Mode symbol/date/time MC#01 000001 — Clerk descriptor/Mc-No./consecutive No. INIT — INIT symbol (C) 2005 by CASIO COMPUTER CO.,LTD. — Copyright All rights reserved. TE-2200/2400 STD — Model name VER. :nnnn —...
If 10 Fs are not shown or another character are shown, RECEIPT JOURNAL FEED FEED immediately set the mode switch to OFF and restart from the beginning of this procedure. 5. Enter “8888888888” and press <CHECK TEND> to complete. After completion, receipt is issued. TE-2200/2400 Dealer's Manual...
Initialization Entering diag mode 1. Plug the power cord into an AC outlet. RECEIPT FEED 2. Hold down <JOURNAL FEED>. REG2 REG1 X2/Z2 3. Turn the mode switch to PGM position. 4. Release <JOURNAL FEED>. 5. Enter “99990000” and press <SUBTOTAL> to enter the diagnosis. RECEIPT JOURNAL FEED...
To avoid repetition, the above operation is abbreviated to the following for all of the other procedure in this manual. This password is defined during initialization operation. TE-2200/2400 Dealer's Manual...
6 s Mode switch File record number (see next pages.) File attribution code (see below.) File number (see next pages.) Consolidation file File attribu- tion code daily sales Periodic 1 Periodic 2 Daily sales Periodic 1 Periodic 2 TE-2200/2400 Dealer's Manual...
Page 24
File allocation programming (P5) File number list File Record Max No. Attribu- Allocat- Default File description Description length of records tion able Rec. No. System files Auto-program work Work Consecutive number work Work Terminal connection table Program Printer connection table Program Start date Buffer...
Page 25
Program *A: Depend on the model. *B: Allocate if you select “check tracking pattern” initialization, (refer to page 24 of this manual). *C: Allocate if you select “scanning pattern” initialization, (refer to page 24 of this manual). TE-2200/2400 Dealer's Manual...
Page 26
*C: Allocate if you select “scanning pattern” initialization, (refer to page 24 of this manual). *D: Allocate these files if you want to change the default message. *E: 67 for TE-2200, 77 for TE-2400Eu, 70 for TE-2400US. *F: 84 for TE-2200, 112 for TE-2400.
— Sales file record length/No. of records of daily sales/periodic sales 1/periodic sales 2 22bytes — Consolidation file record length/No. of records of daily sales/periodic sales 1/periodic sales 2 10bytes FILE0002 — Hyphen means no record. 35bytes 10bytes — Remaining RAM capacity 20,234 TE-2200/2400 Dealer's Manual...
Set a function to the 4th menu sheet. Set a function to the 5th menu sheet. Set a function to the 5th menu sheet. Set a function to the 6th menu sheet. Set a function to the 6th menu sheet. TE-2200/2400 Dealer's Manual...
Key allocation programming (P4) Configuration of the physical key layout TE-2200 RECEIPT JOURNAL FEED FEED TE-2400 for Eu RECEIPT JOURNAL FEED FEED TE-2400 for US RECEIPT JOURNAL FEED FEED The shadowed key cannot be programmed with any other functions. <00>, <000>, and <.> functions are only allocated to <#011> or <#012> keys.
Page 31
Text recall Multiplication Three zero New balance New check NEW CHK Tray total TRAY TL New/old check NEW/OLD Two zero No sale Validation Non-add Non-add/No sale #/NS Void VOID * These functions cannot be allocated on TE-2200. TE-2200/2400 Dealer's Manual...
Reset consecutive number after daily fixed total reset report is issued. No = 0 Always “0” : : : : : : ; ; ; ; ; ; Consecutive number set value. It starts “set value + 1.” TE-2200/2400 Dealer's Manual...
Yes = 1 Yes = 0 Print number of customers on header. (a+b+c) (a+b+c) No = 2 No = 0 Print PLU number on receipt. Yes = 4 *1: Select “Yes” if you want to print receipts with watermarks. TE-2200/2400 Dealer's Manual...
Key function/machine feature (P3) Address code 06 (calculation & operation control) Description Choice Program code Initial value Yes = 0 Follow the taxable status and commission status of previous item when +/- No = 1 operation is performed. No = 0 Force to register rate tax before finalization.
No = 0 Summed up menu sheet 6 to parent menu sheet. Yes = 4 Always “0” Yes = 0 Reset child menu sheets with parent menu sheet together. No = 1 This program is not effective for TE-2200. TE-2200/2400 Dealer's Manual...
Key function/machine feature (P3) Address code 08 (print control for fixed total report) Description Choice Program code Initial value Yes = 0 Print gross sales total on fixed total report (GROSS) No = 1 Yes = 0 Print net sales total on fixed total report (NET) No = 2 (a+b+c) (a+b+c)
Print taxable amount 10 total on fixed total report (TA10) No = 1 Yes = 0 Print tax 10 total on fixed total report (TX10) No = 2 (a+b+c) (a+b+c) Yes = 0 Print tax exempt 10 total on fixed total report (EX10) No = 4 TE-2200/2400 Dealer's Manual...
Decimal for CECA4 and CECK4 in fixed total report: 2 = 1 1 Period = 0, 2 Comma = 1 (a+b) (a+b) 1 = 0 Separator for CECA4 and CECK4 in fixed total report: 2 = 4 1 Comma = 0, 2 Period = 1 TE-2200/2400 Dealer's Manual...
Key function/machine feature (P3) Address code 15 (print control for reports) Description Choice Program code Initial value Yes = 0 Zero skip department report. No = 1 (a+b) (a+b) Yes = 0 Zero skip clerk report. No = 2 Yes = 0 Zero skip transaction report.
Print grand total 1 on daily sales reset report. No = 1 Yes = 0 Print grand total 2 on daily sales reset report. No = 2 (a+b+c) (a+b+c) Yes = 0 Print grand total 3 on daily sales reset report. No = 4 TE-2200/2400 Dealer's Manual...
Merge the same department/PLU/scanning PLU registration on order receipt. Yes = 4 (Item consolidation) Significant Number of feed lines before order printing (0 ~ 9) number Significant Number of feed lines after order printing (0 ~ 9) number TE-2200/2400 Dealer's Manual...
Key function/machine feature (P3) Address code 21 (message control) Description Choice Program code Initial value Print graphic type logo. No = 0 (If select “No”, character type logo is printed.) Yes = 2 (a+b) (a+b) No = 0 Print watermark on receipt. Yes = 4 No = 0 Print commercial message on slip/guest receipt.
Print of clerk/cashier's name on receipt following sign back on at D = 1. No = 0 (enable clerk/cashier interrupt) Yes = 4 Always “0000000” Significant Auto sign-off timer. (in second) (“00” means no auto sign-off.) numbers TE-2200/2400 Dealer's Manual...
Key function/machine feature (P3) Address code 28 (Euro) Description Choice Program code Initial value Yes = 0 Define Euro as the main currency. No = 1 Significant Select rounding option: number (0 ~ 2) Round off = 0, Cut off = 1, Round up = 2 : : : : : : ;...
Skip the bottle link field programming of direct maintenance PLU file in No = 0 (a+b+c) (a+b+c) PGM 3 mode. Yes = 2 Skip the mix & match field programming of direct maintenance PLU file in No = 0 PGM 3 mode. Yes = 4 Always “00” TE-2200/2400 Dealer's Manual...
Key function/machine feature (P3) Address code 33 (batch PLU maintenance) Description Choice Program code Initial value No = 0 Skip the record No. designation of batch maintenance PLU file. Yes = 1 (a+b) (a+b) No = 0 Skip the optimum stock field programming of batch maintenance PLU file. Yes = 4 No = 0 Skip the unit price field programming of batch maintenance PLU file.
Auto check ending number (0000 = 9999) * numbers (0000 ~ 9999) * The starting number should be smaller than the ending number. * If the starting number is bigger than the ending number, the E056 is occurred. TE-2200/2400 Dealer's Manual...
Key function/machine feature (P3) Department key/flat-PLU key/PLU program (Batch feature programming) Programming procedure To another department/flat-PLU key Department/flat-PLU key Department 6 3s 6 B MENU SHIFT Mode switch Program data Flat-PLU (12 digits) To a new (not sequential) PLU Different program to the next PLU 6 3s 6 6 a 6s PLU No.
Key function/machine feature (P3) Department key/flat-PLU key/PLU program (Individual feature programming) Programming procedure Department/flat-PLU key To another department/flat-PLU key Same program Department 6 3s 6 66s 6 Flat-PLU Mode switch Program data Address code To a new (not sequential) PLU Different program to the next PLU Same program : :66s...
Page 55
Print order to “Order 1 (printer connection table)” printer. Yes = 1 No = 0 Print order to “Order 2 (printer connection table)” printer. (a+b+c) Yes = 2 No = 0 Print order to “Order 3 (printer connection table)” printer. Yes = 4 Always “00” TE-2200/2400 Dealer's Manual...
Page 56
Key function/machine feature (P3) Address code 17 (Bon receipt control) Description Choice Program code Significant Number of Bon receipts (1 ~ 9) number (If “0”, no Bon is issued.) Other address code Address Description Choice Program code code Significant Single item control: number Normal receipt = 0, Single item receipt = 3 No = 0...
*3 Those are valid options for Cashing a check as well. *4 Those are valid options for Currency exchange (include partial tender) as well. *5 Those are valid options for Media change (include partial tender) as well. TE-2200/2400 Dealer's Manual...
Page 58
Key function/machine feature (P3) <CREDIT> Description Choice Program code No = 0 Restriction (to 0, 5) on last digit for amount tendered. Yes = 1 Significant number Allowable number of validation printing (“0” means no limitation) (0 ~ 9) No = 0 Force validation operation.
Operation error = 0, Auto Cash = 1, New balance = 2 No = 0 Print VAT breakdown. Yes = 1 (a+b) Amount = 0 Service charge 1 Use an amount 2 Use a rate Rate = 2 ; ; ; ; ; Always “00000” TE-2200/2400 Dealer's Manual...
Page 60
Key function/machine feature (P3) <CHARACTER RECALL>, <CHARACTER PRINT> Description Choice Program code No = 0 Disable operation in RF/REG– mode. Yes = 1 No = 0 Disable operation in REG2 mode. Yes = 2 (a+b+c) No = 0 Disable operation in REG1 mode. Yes = 4 Always “0”...
Page 61
Yes = 4 ; ; ; ; Always “0000” Maximum value (0 ~ 9) High amount limit specification for entering amounts Number of zeros (0 ~ 9) Always “00” These programmable options are not effective for the Euro function. TE-2200/2400 Dealer's Manual...
Page 62
Key function/machine feature (P3) <+ (PLUS)>, <- (MINUS)>, <COUPON> Description Choice Program code Yes = 0 Multiple validation (If “No”, only one validation printing is possible.) No = 4 Always “0” No = 0 Disable operation in RF/REG– mode. Yes = 1 No = 0 Disable operation in REG2 mode.
Page 63
Credit 1 = 3, Credit 2 = 4, Credit 3 = 5, Credit 4 = 6 Maximum value (0 ~ 9) High amount limit specification for entering amounts Number of zeros (0 ~ 9) Always “00” TE-2200/2400 Dealer's Manual...
High digit limitation (00 ~ 10), “00” means no limitation. numbers Always “00” Usage:Both CLOCK-IN and CLOCK-OUT = 0, Significant CLOCK-IN only = 1, CLOCK-OUT only = 2 number Yes = 0 Issue receipt during CLOCK-IN/OUT. No = 1 TE-2200/2400 Dealer's Manual...
Key function/machine feature (P3) Clerk program Secret number, drawer, check number programming Programming procedure To a new (not sequential) clerk To the next clerk : : : : 6 3s 6 6 a 6 s 07s6 Record No. Mode switch Data Description Choice...
No = 0 Disable to sign on (a+b+c) Yes = 2 No = 0 Sign off at finalization (secret number only) Yes = 4 Always “0” No = 0 Compulsory Eat-in/Takeout operation Yes = 2 Always “00” TE-2200/2400 Dealer's Manual...
Page 85
Actual value of difference of the non-cyclic and cyclic values .... 0 : : : : Tax table No. (0125 ~ 1025) Mode switch 8^25a Tax rate (2-digit for integer + 4-digit for decimal) Tax table maximum value (“0” means unlimited). 5002a Rounding/tax table system code TE-2200/2400 Dealer's Manual...
Page 86
Key function/machine feature (P3) Example 2: U.S. tax table without rate setting Max. break point Price range Difference Pattern Upper Lower (6%) Min. break point Max. break point 10 – $ .00 $ .01 $ .10 Non cyclic 24 – 10 = 41 –...
Page 87
Sum of values in each non-cyclic pattern 0714a 1414a Actual value of difference of the non-cyclic and cyclic values. 1514a 1415a You must enter these values in 4-digit block. If the last block comes out to be only two digits, add two zeros. TE-2200/2400 Dealer's Manual...
Page 88
Key function/machine feature (P3) Example 4: Add-in rate tax Tax rate (2-digit for integer + 4-digit for decimal) ....... 10.00 % Rounding/tax table system code............0003 (Cut off) : : : : Tax table No. (0125 ~ 0325) Mode switch Tax rate (2-digit for integer + 4-digit for decimal) Always “0”...
Department = 15, Group = 16, Clerk = 17, Time zone = 19, Monthly = 20, numbers Scanning PLU = 26, Table analysis = 28, Employee = 29, Mix & match = 61, PLU stock = 64, PLU stock by group = 34 TE-2200/2400 Dealer's Manual...
Key function/machine feature (P3) Arrangement programming Programming procedure 6 3s 6 38s 6 A6 Arrangement table No. (up to 6 digits) Record No. Mode switch (up to 4 digits) 6 A 6 s Key operations * The same should be pressed. ** Vacant record search: If you want to set an arrangement program to a new record, “vacant record search”...
Key function/machine feature (P3) Employee number programming Programming procedure To a new (not sequential) record To the next record 6 3s 6 61s 6 6a 6 s Program data Mode switch Record No. Program data Description Choice Program code Significant Employee number (0000000001 ~ 9999999999) numbers...
Key function/machine feature (P3) Job command table Description Job No. Group/terminal ID Parameter Default menu sheet number after signing on. (D of address code 70 of clerk programming) 030770 0cddee Disabled menu sheet number (D of address code 70 of clerk programming) 030771 fgddee Switching to dual (Euro/local) currency system to Euro only system...
To a new (not sequential) total To the next record 6 3s 6 73s6 Record No. Mode switch 6 a 6 s Flat- MENU PLU No. : : : : 04a 6 Record No. (4-digits) Random code (6-digits) TE-2200/2400 Dealer's Manual...
Key function/machine feature (P3) I/O parameter table programming Programming procedure To a new record To the next record 6 3s 6 98s 6 6 a6 s Program data Record No. Mode switch Note: Please perform the following procedure after this program. 1.
Key function/machine feature (P3) Non PLU table programming To a new record Programming procedure To the next record 6 3s 6 40s 6 6 a6 s Program data Record No. Mode switch Program data Description Choice Program code Significant Non PLU type: Short version = 0, Long version = 1 number No = 0...
6a 6 6 a 6 s Bottle link Mix & match Optimum stock Skip by general function programming address code 33. Activation of batch maintenance PLU Activation procedure 6 3s 6 4070s 6 Activation Mode switch Cancellation TE-2200/2400 Dealer's Manual...
Key function/machine feature (P3) Scanning PLU direct maintenance programming Programming procedure 63s 6 0071s 6 Mode switch Code 6 a6B 6 PRICE Scanning SHIFT Unit price/quantity Action code Link-# 6 a 6 6a 6 DEPT Status Character 6a 6 6 a 6 6 a 6 s Bottle link Mix &...
Code 6 s 6 B 6 PRICE Scanning SHIFT Address code Address code 22: 6 a 6 character programming Character Link-# Address code 11: link programming DEPT Address code 13,20,21,23: 6 a 6 other programming Program data TE-2200/2400 Dealer's Manual...
Key function/machine feature (P3) Program data Action code Description Choice Program code Action code: Significant Addition = 0 number Modification = 1 Deletion = 2 (Not effective for direct PLU maintenance) Unit price/quantity (Address code 21 for individual feature programming) Description Choice Program code...
Taxable 3 = 3 Taxable 7 = 7 One touch NLU programming Programming procedure To the next record Code 63s 6 77s 6 6 B 6 s Scanning Rec No. (up to 3 digits) Mode switch TE-2200/2400 Dealer's Manual...
TX10 4701 Average sales per customer AVRG 9801 Tax exempt 10 EX10 4801 Check cashing service fee 9901 Nontaxable amount 4901 New balance fee 5001 (not used) * Totalizers for sub currency 5101 Clerk commission 1 total TE-2200/2400 Dealer's Manual...
Page 106
Group 03 GROUP03 9906 Group 99 GROUP99 Clerk character Up to 12 characters Address Initial character Contents code TE-2200/2400 (Eu) TE-2200/2400 (US) 0107 Clerk 01 0207 Clerk 02 0307 Clerk 03 9907 Clerk 99 Table analysis character Up to 12 characters...
Element title 4 of CF X/Z report (16) 4723 Element title 5 of CF X/Z report (16) AMOUNT 4823 Element title 6 of CF X/Z report (16) DISCOUNT 4923 Element title 7 of CF X/Z report (16) TE-2200/2400 Dealer's Manual...
Page 108
7123 element title 29 of CF X/Z report (16) PRICE SHIFT 7223 element title 30 of CF X/Z report (16) TE-2200 7323 model name 1 of CF X/Z report (16) 7423 model name 2 of CF X/Z report (16) TE-2400...
Page 109
9th line of guest bottom message 3932 10th line of guest bottom message INVOICE 4032 1st line of Australian GST MOF message * INDICATES 4132 2nd line of Australian GST MOF message TAXABLE SUPPLY 4232 3rd line of Australian GST MOF message TE-2200/2400 Dealer's Manual...
Character programming (P2) Report header Up to 12 characters Address Contents Initial character code 0124 Fixed totalizer report 0224 Transaction key report TRANS 0324 PLU report 0424 Department report DEPT 0524 Group report GROUP 0624 Cashier/clerk report CASHIER 0724 Not used 0824 Hourly sales report HOURLY...
9961 Employee 99 CSHR99 Help message Up to 24 characters Address Contents Initial character code 00185 Help message 001 ENTER NUMBER THEN 00285 Help message 002 PRESS <HELP> KEY. 00385 Help message 003 19985 Help message 199 TE-2200/2400 Dealer's Manual...
Character programming (P2) Terminal connection table Up to 8 characters Address Contents Initial character code 0191 Physical No. 01 MC#01 AT command Up to 62 characters Address Contents Initial character code AT COMMAND**** 0196 Command set to MODEM 0296 on hook, confirmation ATI4 Error message Up to 16 characters...
Input Unit Price 0381 Guidance message of NFP 3rd line ,and press DEPT 2281 Guidance message of price comp 4th line > key Online password Up to 8 characters Address Contents Initial character code 0197 Online password TE-2200/2400 Dealer's Manual...
Character programming (P2) Programming item/key descriptors Programming procedure Department key/transaction key To another department/transaction key Department key 6 2s 6 Characters Transaction key See “Entering Mode switch characters” section. To a new (not sequential) PLU To the next PLU 6 2s 6 a 6 s PLU No.
Page 115
Taxable amount subtotal TAST Minus Text print Multiplication/Date/Time Text recall CHAR Multiplication Three zero New balance New check NEW CHK Tray total TRAY TL New/old check NEW/OLD Two zero No sale Validation Non-add Non-add/No sale #/NS Void VOID TE-2200/2400 Dealer's Manual...
Character programming (P2) Programming item/clerk descriptors by range Programming procedure : : s 990000 Mode switch Department = 05 PLU/flat-PLU = 04 Ends “the last record”. Starts “0001”. : : a Start rec-# End rec-# Program data (Max. 4 digits) (Max.
Entering characters By character keyboard TE-2200 character keyboard Example: Input “ ”, enter “DBL”“A” “SHIFT”“p” “p” “l” “e” “SPACE” “CAP”“J” “SHIFT”“u” “i” “c” “e” RECEIPT JOURNAL FEED FEED INS/ SHIFT < — — > DOUBLE • SIZE TE-2200 Eu RECEIPT...
Page 118
SHIFT TE-2400 US /INS 1 Shift key 7 Alphabet keys TE-2200: Use those keys to enter characters. Pressing this key shifts the character through the upper- 8 Numeric keys case letter, lower case letter and numerics. Use those keys to enter program codes, memory number TE-2400: and character codes.
Character programming (P2) Editing characters Correcting a character just entered OPERATION DISPLAY (character) 1 Enter LENON, instead of LEMON. “L” “E” “N” “O” “N” LENON 1 Press left arrow key three times. LENON 1 Override mode INS/ LENON 1 Enter “M”. “M”...
You can use <X>, <X/XX> or <X/KETTEN> instead of these keys. Unit price program Programming procedure Programming the 1st unit price and unit quantity (to department/flat-PLU key) To another department/flat-PLU key Department 6 1s 6 MENU SHIFT Program data Mode switch Flat-PLU (12 digits) TE-2200/2400 Dealer's Manual...
Page 124
Unit price/rate programming (P1) Programming the unit price and unit quantity (to PLU) To a new (not sequential) PLU Different program to the next PLU Same program 6 1s 6 6 a 6 s PLU No. Mode switch Program data (Rec No.: 4 digits) (12 digits) (Random code: 6 digits)
Unit price/rate programming (P1) Issuing program reading report of program 1 mode Issuing procedure 6 1s 6 s Mode switch Report sample P01....— Program read symbol — Transaction key unit price or rate CASH @100.00 CHECK @1.00 @1.00 — Department descriptor/rec-#/file-# DEPT01 0001-05 —...
Program reading (P6) Department Program 1 — Program 1 mode symbol P01....— Department range #0001 - #0010 — Department descriptor/rec-#/file-# DEPT01 0001-05 — Unit quantity/unit price 1.23 @10.00 DEPT02 0002-05 2.34 @30.00 Program 2 — Program 2 mode symbol P02....
Scanning PLU — Program 3 mode symbol P03....— Scanning PLU descriptor SCAN-PLU0001 — Scanning PLU code #49401004 — Unit quantity/unit price @10.00 — Menu sheet No./status/link dept/ 0 000000 000100 0000 00 bottle link/mix & match TE-2200/2400 Dealer's Manual...
Program reading (P6) Table analysis Program 2 P02....— Program 2 mode symbol TBL01 0001-18 — Table descriptor/rec-#/file-# TBL02 0002-18 TBL03 0003-18 Program 3 — Program 3 mode symbol P03....— Table descriptor/rec-#/file-# TBL01 0001-18 — Program data 000000000000 TBL02 0002-18 000000000000 TBL03...
— ID character/rec-#/file-# MC#01 0001-91 Program 3 — Program 3 mode symbol P03....— ID character/rec-#/file-# MC#01 0001-91 — Program 1001 Printer connection table — Program 3 mode symbol P03....— Rec-#/file-#/program 0001-93 000000 0002-93 100000 0003-93 000000 TE-2200/2400 Dealer's Manual...
Program reading (P6) AT command P02....— Program 2 mode symbol 0001-96 — Rec-#/file-# AT command ************* — Program ************************ ************** 0002-96 Online password P02....— Program 2 mode symbol PASSWORD 0001-97 — Program/rec-#/file-# I/O parameter table P03....— Program 3 mode symbol —...
Program guidance message — Program 2 mode symbol P02....— Guidance No. (internal use) #0001 — Message/rec-#/file-# Range PGM 0001-83 Input start No. 0002-83 and press <#1> 0003-83 #0002 Range PGM 0001-83 Input end No. an 0004-83 TE-2200/2400 Dealer's Manual...
Command code 9xx (xx: file No.) This function copies the specific terminal program file (except system work files) without counters and totalizers. When the specific file is not reserved on the target terminal, it is allocated automatically. TE-2200/2400 Dealer's Manual...
Page 142
Auto-programming/system utilities (P7) Command code list File Command Command Command Command File description 090/990 092/992 0xx/9xx System files Consecutive number work Terminal connection table 091/991 Printer connection 093/993 Start date Initialize code AT command 096/996 Online password 097/997 I/O parameter table 098/998 System error log Function and total files...
If you use the CF card for the first time, format it. From CF card File selection by 6 7s 6 20s 6 (Execution) the cursor keys Mode switch (Cancellation) Cursor keys TE-2200 TE-2400 Up cursor key Up cursor key Down cursor key Down cursor key...
— Start date START DATE 04-03-2006 ------------------------ — Rec-#/job No./error code (Refer to the appendix.)/date 01 0001 0001 000505 — Time/destination terminal ID 1058 0102 02 0000 0000 000000 0000 0000 03 0000 0000 000000 0000 0000 TE-2200/2400 Dealer's Manual...
Page 146
(Cancellation) Deleting a file from CF card File selection by 6 7s 6 30s 6 (Execution) the cursor keys Mode switch (Cancellation) Cursor keys TE-2200 TE-2400 RECEIPT JOURNAL FEED FEED Up cursor key Up cursor key Down cursor key Down cursor key...
Page 147
Modem set ------------------------ AT&V — Modem response ACTIVE PROFILE: Normal End Set the graphic logo to the external printer Before executing this command, you should connect UP-350. 6 7s 6 4350s 6 a (Execution) Mode switch (Cancellation) TE-2200/2400 Dealer's Manual...
Drawer 2 = 2 Note: 1. Each clerk can be assigned a drawer when optional multi-drawer system is being used. 2. Input a 4-digit clerk number (0001 ~ 9999) that identifies the clerk you want to assign the drawer to. TE-2200/2400 Dealer's Manual...
Manager operation Stock quantity maintenance (PLU/flat PLU/scanning PLU) You can make changes in actual stock quantities for PLU using the procedures described in this section. To add to the actual stock quantity of a PLU/flat PLU/scanning PLU To a new PLU Procedure for PLU To the next PLU Same value to...
Clerk No. (4 digits) clerk interrupt (Max. 6 digits) To link clerk numbers to clerk number keys Procedure To other clerk : : : : 6 o 6 Clerk No. (4 digits) Note: To clear the programming, enter “000000.” TE-2200/2400 Dealer's Manual...
Manager operation Programming for the Euro This procedure is used for defining main/sub currency, currency exchange rate for the Euro, and drawer number for sub currency at the same time. Please follow the guidance receipts issued in each time during this procedure. General procedure Guidance Guidance...
Page 153
<CHECK>, <NB>, <+>, <–>, <COUPON>) are set to zero. Automatic execution of this procedure on the preset date/time You can execute this Euro switchover procedure automatically by using arrangement and scheduler. Please refer to the programming example on page 184. TE-2200/2400 Dealer's Manual...
Manager operation Programming for the Australian GST This procedure is used for defining • Tax symbol (*) is printed. • Taxable amount (receipt) is skipped. • “GST INCLUDED” is set to the TX1 descriptor. • “TAXABLE AMT” is set to the TA1 descriptor. •...
The report header message is programmable up to maximum of 12 characters. Note that the report header is pro- grammable for each totalizer file or for batch X/Z report file record, not for each report code. TE-2200/2400 Dealer's Manual...
Read/reset report Programmability Report issuance can be programmed with the following features: • Suppress printing of zero total lines. • Money declaration compulsory • Report header message (report title) • Print sales ratio • Suppress printing of grand total • Print two copies of the fixed total reset report. •...
Page 157
Mode switch Note: Press to terminate this procedure. If you skip to enter the start No., it starts the first record No./random code. If you skip to enter the end No., it starts the last record No./random code. TE-2200/2400 Dealer's Manual...
Page 158
60514 best 50 (quantity order) 70014 70114 70214 70314 70414 70514 by group #124 #224 #424 #524 menu (1st) (except TE-2200) #181 #281 #481 #581 menu (2nd) (except TE-2200) #182 #282 #482 #582 menu (3rd) (except TE-2200) #183 #283 #483...
Page 159
Report code Mode switch Report code Report name Daily Periodic 1 Periodic 2 PLU reset (no report) 50014 51114 51214 Scanning PLU reset (no report) 50026 ----- ----- Scanning PLU stock reset (no report) 50065 ----- ----- TE-2200/2400 Dealer's Manual...
— Tax amount 1 total $136.48 EX10 $487.58 — Nontaxable amount NON TAX $9.75 ------------------------ — Grand total 1 $00000000462846.73 — Grand total 2 $00000000645230.72 — Grand total 3 $00000000449096.81 — Consecutive number range of the day 011462--->012343 TE-2200/2400 Dealer's Manual...
$9.37 #000101 ------------------------ ------------------------ 207.933 — Quantity total $389.80 — Total column of not classified items $2,871.63 — Amount total RED PRC $1.98 RED PRC $44.31 — Red price total DISCOUNT $9.37 DISCOUNT $86.53 — Discount total TE-2200/2400 Dealer's Manual...
Read/reset report Best 50 report 1..— Ranking PLU0001 83.933 — PLU character/quantity 25.27% $1,373.39 — Sales ratio/amount OLD PRC $26.35 — Old price total RED PRC $18.98 — Red price total DISCOUNT $56.37 — Discount total #000001 — PLU code (4-digit) or Random code (6-digit) 2..
— Red price total RED PRC $18.98 — Discount total DISCOUNT $56.37 DEPT02 4.37% $63.44 DISCOUNT $0.00 ------------------------ — quantity total 207.933 — Amount total $2,871.63 — Red price total RED PRC $44.31 DISCOUNT $86.53 — Discount total TE-2200/2400 Dealer's Manual...
Read/reset report Best 50 report — Ranking 1..— Department character/quantity DEPT01 83.933 — Sales ratio/amount 25.27% $1,373.39 — Old price total OLD PRC $26.35 — Red price total RED PRC $18.98 — Discount total DISCOUNT $56.37 2..DEPT50 21.19% $1,152.06 OLD PRC $66.75...
PLU Z clear Normal End — Action/result Scanning PLU reset — Mode symbol/date/time 03-04-2006 22:30 — Clerk descriptor/Mc-No./consecutive No. MC#01 000051 — Report header/title/reset counter SCAN PLU 0001 — Report code 0051026 — Action/result PLU Z clear Normal End TE-2200/2400 Dealer's Manual...
PLU type UPC-A 11 digits without check digit UPC-E 6 digits without check digit EAN-13 (JAN-13) 13 digits with check digit Non PLU type EAN-8 (JAN-8) 8 digits with check digit UPC-A 11 digits without check digit TE-2200/2400 Dealer's Manual...
Application systems PLU maintenance There are three ways to maintain scanning PLU, i.e. not found PLU maintenance, batch PLU maintenance and direct PLU maintenance. Not found PLU maintenance When an item which code is not existed in the scanning PLU file is registered, the “Not found” error occurs. You can register this item by not found PLU maintenance procedure.
•1.00 (scan) ————————— “Not Found Error” #49012361 Dept. •2.00 ————————————— 100! Scan-PLU ($1.00) CASH •2.00 Item 2 ————————— Input price and press the linked (scan) PLU code 49012361 department key. ————————————— “Scanning” Payment Cash $2.00 Register normally. TE-2200/2400 Dealer's Manual...
Page 178
Application systems Price change operation When a scanning PLU item is programmed to enable to change price, you can change the unit price temporarily. The preset price in the scanning PLU file is not changed by this operation. You can restrict the temporary price is less/greater than the programmed unit price by the general function program.
Application systems Discount type 3: In this type of processing, a discount is made when the quantity of a particular scanning PLU reaches a certain number during registration. And this discount is made after this item registration. OPERATION RECEIPT Scan-PLU ($0.34) “Scanning”...
3. The destination of bill copy is programmable. “Buffered print” of the address 05 of the general function is necessary. 4. You cannot back up the printouts to the R/J printer to external printers. That is, R/J printer is the last backup printer. TE-2200/2400 Dealer's Manual...
Application systems Printing control options for order Below shows the summary of the programmable options for order printing. local/ Program Programmable option for R/J remote location printer Number of feed lines before order printing (1 ~ 9) Address code 19 of the general control program Number of feed lines after order printing (1 ~ 9) Address code 19 of the general control program Cut order...
After pressing <EAT-IN> or <TAKEOUT>, only finalize operation is possible. The compulsion is released by <OPEN2>, so be sure to allocate this key before using this function. Receipt sample 1 HAMBURGER •2.00 1 POTATO •1.50 1 COKE •1.00 TAKE-OUT TE-2200/2400 Dealer's Manual...
Tips Automatic execution of Euro switchover by arrangement and scheduler The following sample shows an automatic execution program of arrangement and scheduler. Sample program Execution date/time: 31. December 2003 23:59 Currency definition type: 3 (Main currency = Euro, Sub currency = Local, Change = Euro) Currency conversion rate: 1 Euro = 6.55957 F Franc Drawer of sub currency: Main...
Page 186
Appendix (Calculation method) Total or Counter Increments or Decrements by Medium in drawer Sales total or tendered total by specified medium + Received on account total (Cash in drawer only) (Cash, charge, check, credit, – Paid out (Cash in drawer only) Food stamp, EBT) + Loan totals (by selected medium) –...
Appendix (Font table) Special font set Slavic (Windows code page 852) Special initialization code D = 010 Chara Code Chara Code Chara Code Chara Code Chara Code Chara Code Chara Code Chara Code Ç É á Ó – ü Ĺ í...
35 bytes 1200 OFF OFF Character code set Katakana PC437 2400 ON OFF Pin 6 (DSR) reset signal Enabled Disabled 4800 OFF ON Pin 25 (INIT) reset signal Enabled Disabled 9600 ON ON * Please select this option. TE-2200/2400 Dealer's Manual...
Appendix (File record format) Scanning PLU files Scanning PLU file (daily) File name: Scanning PLU File No.: 016 Max. allocatable records: Depend on the model 24 27 35 37 39 40 Minimum Actual PLU code Character Link stock Counter Totalizer stock Non PLU table file (program) File name: Non PLU table...
Communication control Direct maintenance PLU Print control (currency exchange totalizers) Batch PLU maintenance Report control (1) Backlight control Report control (2) (future use) Report control (3), Money declaration Store/Recall range Slip/Guest/KP print Auto check range Order control TE-2200/2400 Dealer's Manual...
Appendix (File record format) Special character file Special character File name: Special character File No.: Max. allocatable records: 42 (fixed) Character See page nn of this manual for the detail of each record. Report header file Report header File name: Report header File No.: 024 Max.
Max. allocatable records: depends on the model Key/character key table record No. TE-2200 RECEIPT JOURNAL FEED FEED TE-2400 (Eu) RECEIPT JOURNAL FEED FEED TE-2400 (US) RECEIPT JOURNAL FEED FEED No character can be programmed to shadowed keys. TE-2200/2400 Dealer's Manual...
Item registration is prohibited, while partial tender. (2/2) E030 E030 Error code (do NOT change) Press RATE TAX k PRESS RATE TAX K Finalization of a transaction attempted without registering rate-tax. (1/2) Finalization of a transaction attempted without registering rate-tax. (2/2) TE-2200/2400 Dealer's Manual...
Page 210
Appendix (File record format) Rec-No. Meaning Default (English) message Error code (do NOT change) E031 E031 Press ST key Finalization of a transaction attempted without confirming the subtotal. PRESS ST KEY Error code (do NOT change) E032 E032 Finalization of a transaction attempted without confirming of the food stamp subtotal. Press FSST key PRESS FSST KEY E033...
Page 211
PROTECT SWITCH Error code (do NOT change) E205 E205 Can not write, because designated file has already been in the CF card or internal File already exi FILE ALREADY EXI flash memory. (1/2) Same as above (2/2) TE-2200/2400 Dealer's Manual...
Page 212
Appendix (File record format) Rec-No. Meaning Default (English) message Error code (do NOT change) E066 E066 Attempt to print the last separated transaction on slip. (1/3) Print from the b PRINT FROM THE B Attempt to print the last separated transaction on slip. (2/3) eginning of the EGINNING OF THE Attempt to print the last separated transaction on slip.
Main currency monetary symbol for Australian GST Taxable 1 symbol for Australian GST Subtotal key descriptor (display) for Australian GST R N D / S T Delete file in the CF card. D E L E T E TE-2200/2400 Dealer's Manual...
Appendix (File record format) Printing guidance message file File name: Printing guidance message File No.: 079 Max. allocatable records: 85(fixed) Character Rec-No. Meaning Default (English) message 001-4 not used Direct maintenance result: success D i r e c t M a i n t e N o r m a l E n d Direct maintenance result: failure...
Page 215
C L O C K - O U T CF card data save: success C A R D N o r m a l E n d CF card data save: failure C A R D E r r o r E n d TE-2200/2400 Dealer's Manual...
Appendix (File record format) X/Z guidance message file File name: X/Z guidance message File No.: 082 Max. allocatable records: 48(fixed) Character Rec-No. Meaning Default (English) message PLU range report message 1st line PLU by range [PLU BY RANGE] Input start No. message 1st line Input start No.
Page 217
Failed result message of master reconnection 2nd line N ERROR END Busy Reset Busy reset message 1st line BUSY RESET Busy reset message 2nd line Input CHK/TBL# a INPUT CHK/TBL# A nd press <#1> Busy reset message 3rd line ND PRESS <#1> TE-2200/2400 Dealer's Manual...
Appendix (File record format) Program guidance message file File name: Program guidance message File No.: 083 Max. allocatable records: 93(fixed) Character Rec-No. Meaning Default (English) message Range program message 1st line Range PGM RANGE PGM Input start No. message 1st line Input start No.
Page 219
Program reading by range message 1st line (quote from rec-03) PGM read PGM READ Input start No. message 1st line (quote from rec-002) Input start No. INPUT START NO. Input start No. message 2nd line (quote from rec-003) and press <#1> AND PRESS <#1> TE-2200/2400 Dealer's Manual...
Page 220
Appendix (File record format) Rec-No. Meaning Default (English) message Please wait message Please wait PLEASE WAIT INLINE AUTO PGM Auto-program (register to register) message INLINE AUTO PGM Input target machine No. message 1st line Input Term/GP No INPUT TERM/GP NO .
Appendix (File record format) Help message file File name: Help message File No.: 085 Max. allocatable records: 199 (fixed) Character Note: It is necessary to allocate this file, if you want to make your original help. Rec-No. Meaning Default (English) message ENTER NUMBER THEN Header message of help receipt (1/19) PRESS <HELP>...
Page 223
Third help item message (16/26) 6)YYZZ <CASH> KEY Third help item message (17/26) Third help item message (18/26) 7)PRESS <SUBTOTAL> KEY. Third help item message (19/26) Third help item message (20/26) XX.XXXX=RATE Third help item message (21/26) YY=00(CUT OFF) TE-2200/2400 Dealer's Manual...
Page 224
Appendix (File record format) Rec-No. Meaning Default (English) message Third help item message (22/26) YY=50(ROUND OFF) Third help item message (23/26) YY=90(ROUND UP) Third help item message (24/26) ZZ=02(ADD-ON) Third help item message (25/26) ZZ=03(VAT) Third help item message (26/26) Fourth help item message (1/20) 04:HOW TO REPLACE Fourth help item message (2/20)
Page 225
Fifth help item message (57/64) Fifth help item message (58/64) Fifth help item message (59/64) Fifth help item message (60/64) Fifth help item message (61/64) Fifth help item message (62/64) Fifth help item message (63/64) Fifth help item message (64/64) TE-2200/2400 Dealer's Manual...
E041 Force to print validation. Insert paper and press <VALID>. E044 Force to print check. Insert check to slip and press <CHK PRT>. E045 Force to print check endorsement. Insert check to slip and press <CHK ENDS>. TE-2200/2400 Dealer's Manual...
Perform slip printing operation. E047 Attempt to register a new transaction without printing slip. Print bill No paper is inserted or paper is out in the slip printer. Insert new slip paper. E048 Insert slip paper and retry TE-2200/2400 Dealer's Manual...
Page 230
Appendix (Error code) Error code (…continued) Error Message Meaning Action code Check tracking index memory full. Finalize and close the check number currently used. E049 CHECK memory full Check tracking detail memory full. DETAIL memory full Finalize and close the check number currently used. E050 Attempt to made use <New Check>...
Page 231
Not found PLU area error 5302 Negotiation error 2018 Online port open error 5303 AT command sending error 2019 No response 5304 Control ER error 2020 File not found 5305 Receive status error 2021 File create error TE-2200/2400 Dealer's Manual...
CF card directory report 146 character code 119 character key table 26 character key table file 205 character keyboard 117 character print 60 character recall 26, 60, 127, 135 character recall file 204 charge 31, 57, 115 check 57, 125 TE-2200/2400 Dealer's Manual...
Page 234
Index date order 33 general control 26, 127, 132 date setting 123 general control file 201 decimal point 31, 115 general control program 33 declaration 31, 38, 79, 115, 160, 161, 167, 186 grand total 25, 106, 127, 132, 186 deleting a file from CF card 146 grand total file 201 department...
Page 236
Index program / message / buffer file 26 scanning PLU 25, 127, 131, 159, 175 program 1 programming in X1 mode 149, 154 scanning PLU best 50 by range department 158 program guidance message 26, 113, 127, 139 scanning PLU by range department 158 program guidance message file 218 scanning PLU by range group 158 program reading report of program 1 126...