Johnson Controls P2000 Hardware Installation page 4

Security management system / enclosure with power supply
Hide thumbs Also See for P2000:
Table of Contents

Advertisement

UNDERWRITERS LABORATORIES COMPLIANCE VERIFICATION SHEET
The following model number is listed under Underwriters Laboratories® (UL) 1076 for Proprietary
Burglar Alarm Units and Systems, UL 294 for Access Control Systems Units and Underwriters
Laboratories of Canada ULC/ORD-C1076-86.
When installed at the site the following requirements must be met to comply with these standards.
1. The CKM-CE75-E1M must be installed within the protected premise.
2. The CKM-CE75-E1M may be used with Models CKM-EP1501, CKM-MR51E, CKM-MR50,
and CKM-MR50-S3 found in file BP4166, Vol. 2, Sec. 9.
3. Power to Models CKM-EP1501, CKM-MR51E, CKM-MR50, and CKM-MR50-S3 shall be
provided via Listed Model F8P.
4. Four hours of standby power for the CKM-CE75-E1M shall be provided by Listed EB-80
battery box and minimum one 12 VDC, 40Ah sealed lead acid battery.
5. CKM-CE75-E1M battery output connections BAT+ and BAT- must be connected to battery via
LifeSafety Power Listed Model BDM (Battery Disconnect Module).
6. The CKM-CE75-E1M must be mounted within 6 feet of the Listed EB-80 battery box.
7. The power supply BAT DET jumper must be installed.
8. The power supply SYS FLT signal must be connected to a Listed subassembly input point
within the same room, not exceeding 100 ft., and enabled at all times
9. The power supply AC FLT signal must be connected to a Listed subassembly input point
within the same room, not exceeding 100 ft., and enabled at all times.
10. If used, the power supply FAI signal must be connected to a Listed subassembly input point
within the same room, not exceeding 100 ft.
11. The NL1 network module has not been investigated for use with the CKM-CE75-E1M.
12. The tamper switch must be connected to a Listed subassembly and enabled at all times
13. Transient protection devices that are installed must not be removed or defeated.
14. Do not connect equipment to an AC power source that is controlled by a switch.
15. UL 294 Performance Levels
Destructive Attack
Endurance
Line Security
Standby Power
CKM-CE75-E1M
Level I
Level IV
Level I
Level IV