Johnson Controls S300 Series Hardware Installation Manual

Johnson Controls S300 Series Hardware Installation Manual

Hide thumbs Also See for S300 Series:

Advertisement

S300
Series
S300-DIN-L
Hardware Installation Manual
December 2017
24-10239-340 Revision B

Advertisement

Table of Contents
loading

Summary of Contents for Johnson Controls S300 Series

  • Page 1 S300 Series S300-DIN-L Hardware Installation Manual December 2017 24-10239-340 Revision B...
  • Page 2 No part of this document may be reproduced without the prior permission of Johnson Controls. If this document is translated from the original English version by Johnson Controls, all reasonable endeavors will be used to ensure the accuracy of translation. Johnson Controls shall not be liable for any translation errors contained herein or for incidental or consequential damages in connection with the furnishing or use of this translated material.
  • Page 3 Declaration of Conformity United States: This equipment, S300-DIN-L, has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 4 UNDERWRITERS LABORATORIES COMPLIANCE VERIFICATION SHEET The following model number is listed under Underwriters Laboratories® (UL) 1076 for Proprietary Burglar Alarm Units and Systems, UL 294 for Access Control Systems Units, and Underwriters Laboratories of Canada  ULC/ORD-C1076-86. S300-DIN-L When installed at the site the following requirements must be met to comply with these standards. The S300-DIN-L is intended to be used with listed sub-assemblies found in file BP4166, Vol.
  • Page 5 CK722 controller and two S300-DIN-RDR2S modules). You can also mount a backup battery unit. The unit is composed of two 12V lead-acid batteries in two battery brackets. 24-10239-340 Rev. B This document contains confidential and proprietary information of Johnson Controls © 2017 Johnson Controls...
  • Page 6: Installation

    Check the purchase order against the packing slips to ensure the order is complete. If the contents of a container are damaged in any way, notify the carrier and your Johnson Controls representative immediately. Report any discrepancies to your Johnson Controls representative. Save the packing materials for possible return shipments. Package Contents Backplate ...
  • Page 7: Hardware Installation

    1. Put one ring terminal over the screw in the side panel and secure with a nut. 2. Put the other ring terminal over the screw in the enclosure door and secure with a nut. Ground strap 24-10239-340 Rev. B This document contains confidential and proprietary information of Johnson Controls © 2017 Johnson Control...
  • Page 8: To Connect Ac Power

    European installations require permanently connected equipment to incorporate a readily accessible disconnect in the fixed wiring. 24-10239-340 Rev. B This document contains confidential and proprietary information of Johnson Controls © 2017 Johnson Controls...
  • Page 9 2. Disconnect the BLU and BRN wires from the terminal block on the power supply. 3. Disconnect the battery cable. 4. Disconnect the two DC power wires. 24-10239-340 Rev. B This document contains confidential and proprietary information of Johnson Controls © 2017 Johnson Control...
  • Page 10 CAUTION Three S300-DIN-RDR2S modules mounted in the S300-DIN-L A CK722 controller and two S300-DIN-RDR2S modules mounted in the S300-DIN-L 24-10239-340 Rev. B This document contains confidential and proprietary information of Johnson Controls © 2017 Johnson Controls...
  • Page 11: Cable Requirements

    When connecting multiple DIN-mounted devices, wire the devices in parallel following the “daisy chain” pattern. To construct the ground wiring, use listed 18 AWG wires. 24-10239-340 Rev. B This document contains confidential and proprietary information of Johnson Controls © 2017 Johnson Control...
  • Page 12 2nd device the last device RS485 Do not connect the DC power cable to a DIN-mounted device until all wiring is complete. CAUTION 24-10239-340 Rev. B This document contains confidential and proprietary information of Johnson Controls © 2017 Johnson Controls...
  • Page 13: Cable Routing

    Where grounding is required, connect only to the proven CAUTION building electrical system ground (earth). 24-10239-340 Rev. B This document contains confidential and proprietary information of Johnson Controls © 2017 Johnson Control...
  • Page 14 Brackets Mounting hardware Adhesive cable tie mounting pads S300-DIN Short and long Cable ties battery wiring battery wiring Figure 3: Battery Bracket Kit 24-10239-340 Rev. B This document contains confidential and proprietary information of Johnson Controls © 2017 Johnson Controls...
  • Page 15 5. Using the S300-DIN battery wiring, connect the batteries to the power supply. 6. Secure the wires to the enclosure using the mounting pads and cable ties. Mounting Battery’s Bracket hardware connectors 24-10239-340 Rev. B This document contains confidential and proprietary information of Johnson Controls © 2017 Johnson Control...
  • Page 16 4. Wire the tamper switch. The switch must be wired to an input point on a DIN-mounted device. Figure 4: Tamper Switch Properly Installed 24-10239-340 Rev. B This document contains confidential and proprietary information of Johnson Controls © 2017 Johnson Controls...
  • Page 17: Specification

    Dimensions: 5.94x3.7x2.56 in (15.1x9.4x6.5 cm) S300-DIN-PA1 Parts accessory Contains a DC power harness, a lock, a tamper switch, and two spare connectors (3-position and 4-position). 24-10239-340 Rev. B This document contains confidential and proprietary information of Johnson Controls © 2017 Johnson Control...
  • Page 18: Environmental Specifications

    5. Connect the battery cable leads to the battery terminals, observing proper polarity connections. 6. Allow the batteries to charge for 12 hours. 7. Verify proper battery operation as described on page 14. 24-10239-340 Rev. B This document contains confidential and proprietary information of Johnson Controls © 2017 Johnson Controls...
  • Page 19: Field Servicing

    Troubleshoot the enclosure by substituting the suspected component with a replacement part. Replacement Parts All replaceable parts are available from Johnson Controls. For instructions on how to obtain order replacement parts, consult your Customer Success Center representative at (800) 482-2778.
  • Page 20 4-position terminal block, 12-24 AWG, to be used to connect the RS485 to the  DIN-mounted device. 3-position terminal block, 12-24 AWG, to be used to connect the power  supply to the DIN-mounted device. 24-10239-340 Rev. B This document contains confidential and proprietary information of Johnson Controls © 2017 Johnson Controls...

Table of Contents