Battery Wiring - Johnson Controls P2000 Hardware Installation

Security management system / enclosure with power supply
Hide thumbs Also See for P2000:
Table of Contents

Advertisement

CKM-CE75-E1M
24-10707-112 Rev. D
Use the following connectors and crimp tool to terminate the standby battery
wiring.
Description
#10 ring terminal, 16-14 AWG to be
used at battery terminal. Two ring
terminals are required.
0.250 series, Ultra-Fast, fully
insulated Faston tab terminal,16-14
AWG to be used to connect battery
to BDM. Two Faston tabs are
required.
B
W
ATTERY
IRING
The following optional configuration is not allowed for UL 294 and UL 1076
installations.
The optional battery backup feature uses one PowerSonic, Model PS-1270,
12 VDC, 7 Ah, sealed lead acid battery per power supply.
The RED (+) and BLK (-) cables are provided with the enclosure. Wire the
battery as shown.
Note: Not all
components of the
CKM-CE75-E1M
are shown.
Components are
not to scale.
When connecting the battery:
Observe polarity.
Make sure battery terminals do not contact the enclosure during installation
or during use.
Manufacturer
TE Connectivity/
Amp
TE Connectivity/
Amp
CKM-CE75-E1M
+ BAT
BLK
RED
+ –
Battery
Figure 3-5: Battery Wiring
3-5
Installation and Wiring
Part Number
Crimp Tool
2-34161-2
58433-3
3-520107-2
58628-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ckm-ce75-e1m

Table of Contents