Migrating From A Previous Operating System - Juniper CTP2000 Series Upgrade

Circuit to packet platform upgrade to ctpos 7.x
Hide thumbs Also See for CTP2000 Series:
Table of Contents

Advertisement

Upgrading the CTP2000 Series Device to CTPOS 7.x

Migrating from a Previous Operating System

16
You should see the following upgrade script output when you complete the steps
described in
"Upgrading with the PP310 Upgrade Kit" on page
output produced when you complete the steps described in
Upgrade Kit" on page 13
is very similar, and you must respond to the same prompts.
Gathering system information.
* Please wait this could take up to 45 seconds.
Found:
System type
PP310
Bios
2.21
Memory installed 1024 MB
Slot 0:
Type T1E1
FPGA 0xea
* needs 0xea
Slot 1:
Type Serial
FPGA 0x73
Slot 2:
Type FXS
FPGA 0x5010150
ID restored
No
Hit return to continue...
This application will prepare the installed hardware for CTPOS 6.0R1. It will
upgrade FPGAs if necessary, upgrade the bios if necessary, and can migrate
the ID of a system running CTPOS 4.6R7 or 5.4R3.
This application will reboot the system multiple times. Please continue the
process through to completion. Failure to do so can leave the system in an
unknown state.
Hit return to continue...
The bios configuration needs to be changed.
Hit return to setup the bios configuration and reboot.
NOTE:
The set and reboot for the BIOS appears only for the PP310 processor.
For the PP332 processor, the BIOS version is 2.14 and a BIOS upgrade is not
required.
11. The upgrade script
"Upgrading with the PP332
Copyright © 2015, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ctp2000-ram-rtm-upgCtp2000-ram-upg

Table of Contents