Fault correction

Fault
Battery indicator on
the operating module
does not light up after
the switch-on.
The
battery
blinks after the switch-
on.
Lighting not active.
40
Cause
Battery fuse is defec-
tive or not correctly in-
serted.
Plug connection of the
power supply without
contact.
gauge
One or both of the drive
motors are switched to
push mode.
Plug connection at one
of the drives without
contact.
Malfunction
electronics.
Not listed faults.
LED-lamp defective.
Lighting fuse or drive
electronics defective.
Remedy
Replace defective fuse
or clean contacts and
insert correctly.
Check the plug connec-
tions.
Move the selection le-
ver for the drive/push
mode into the drive
mode position on both
sides.
Check the plug connec-
tions.
in
the
Have it repaired by the
specialist
(Push mode)
Selection lever in driv-
ing mode position.
View < error diagnos-
tics > in the operating
manual for the operat-
ing module.
Let it be repaired or
replaced by a specialist
workshop.
Let it be repaired or
replaced by a specialist
workshop.