Fault Correction - Meyra SMART 9.906 Operating Manual

Table of Contents

Advertisement

FAULT CORRECTION

Fault
Battery indicator on
the operating module
does not light up after
the switch-on.
The battery indicator
blinks after the switch-
on.
Lighting not active.
62
Cause
Battery fuse is defec-
tive or not correctly in-
serted.
Plug connection of the
power supply without
contact.
Power
motors
switched to push mode.
Plug connection at one
of the drives without
contact.
Malfunction
in
electronics.
Not listed faults.
Filament bulb defec-
tive.
Lighting fuse or drive
electronics defective.
Remedy
Replace defective fuse
or clean contacts and
insert correctly.
Check the plug connec-
tions.
are
Move the selection le-
ver for the drive motors
into the drive mode
position and make sure
it clicks into place.
Check the plug connec-
tions.
the
Have the fault correct-
ed by an authorised
workshop. (Push mode)
Selection lever in driv-
ing mode position.
View < fault diagno-
sis > in the operating
manual for the operat-
ing module.
Replace defective fi la-
ment bulb.
Let it be repaired or
replaced by a specialist
workshop.