Motor connection, shield support and fabrication
4.2 Motor connection block for 45 A / 60 A Motor Modules
Connection using a shield connection clamp
The shield connecting plate, shield connecting terminals and hose clamps are not included in
the scope of supply of the Motor Module.
Table 4- 6
Designation
Shield connection plate
Phoenix SK14 shield connection terminal
Phoenix SK35 shield connection terminal
Hose clamp
4.2.3

Prefabricating a motor connecting cable

The stripped lengths of the motor cables are the same for all cross-sections. The lengths for
the individual conductors are specified below.
1. Remove the cable sheath to 205 mm (8.07 in) length with a tolerance of ±10 mm
(±0.04 in).
2. Shorten the braided shield to 80 mm (3.15 in) and fold it back.
3. If you are using a motor cable with brake conductors, then the braided shield of the brake
conductors must be unbraided. This is then folded back against the outer shield.
4. Fix the braided shield using heat-shrink tubing. Preferably use shrink-on sleeving, which
has hot-melt adhesive on the inside.
90
at the shield connecting plate
Accessories for the shield support
Connection using a hose clamp at the shield
connecting plate
Torque
6 Nm (53.1 lbf in)
0.8 Nm (7.08 lbf in)
0.8 Nm (7.08 lbf in)
0.8 ... 1 Nm
(7.08 ... 8.85 lbf in)
Power Units in Booksize C/D-Type Format
Manual, 12/2018, 6SL3097-5AC20-0BP0
Article No.
6SL3162-1AD00-0AA0
8WH9130-0MA00
8WH9130-0PA00
-