Motor Modules in booksize C/D-type format
3.3 Interface description
Note
Motor connector
For information about the motor connector, please refer to Chapter "Motor connector"
(Page 73).
Note
Shielding
Attach the motor cable shield to the shield connection plate on the Motor Module using the
shield connection clamp supplied in the terminal kit. You can find more detailed information
in Chapters "Motor connector" (Page 73) and "Shielding and routing cables" (Page 123).
Table 3- 2
For ring cable lugs without insulation (Page 119)
1)
Motor holding brake connection
To ensure reliable opening of the motor holding brake, it requires a typical voltage of 24 V ±
10% at the motor connection. Refer to the data sheet of the motor for the motor holding
brake voltage and tolerance.
● Also take into account that voltage drops occur in the motor module and on the supply
cable.
● Use a Control Supply Module or a regulated DC power supply whose setpoint is set to at
least 26 V.
● Note that there are motor holding brakes that close again when the maximum voltage is
exceeded.
48
X1 motor connection and X11 brake connection for Single Motor Modules 45 A and 60 A
Terminal
U2
V2
W2
+ (BR+)
- (BR-)
Technical data
Threaded bolts: M6 / 6 Nm
X11 brake connection connector:
Module output voltage: 24 V DC
Max. load current: 2 A
Minimum load current: 0.1 A
Type: Spring-loaded terminal (Page 118)
The brake connector is part of the prefabricated
cable.
Power Units in Booksize C/D-Type Format
Manual, 12/2018, 6SL3097-5AC20-0BP0