Siemens SINAMICS S120 Manual page 93

Power units in booksize c/d-type format
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

5. Shorten the individual conductors as indicated in the drawing and table below.
6. Use suitable ring or tubular cable lugs (see appendix).
Figure 4-9
Table 4- 7
BR+, BR-
U, V, W, protective conductor
Ring or pipe-type cable lug
Shield
folded back braided shield
Note
Cables for UL applications
For UL applications, only 60/75 °C copper cables may be used.
Power Units in Booksize C/D-Type Format
Manual, 12/2018, 6SL3097-5AC20-0BP0
Holding brake conductors
Conductors U, V, W and protective conductor
Ring or pipe-type cable lug
Protective braided shield
Shrink tubing
Motor connection cables
Required insulation stripping lengths in mm (inches)
Motor connection, shield support and fabrication
4.2 Motor connection block for 45 A / 60 A Motor Modules
Connection using a shield
connection clamp
Length
Tolerance
a
180 (7.09)
±10 (±0.4)
b
145 (5.71)
±5 (±0.2)
c
depending on the cable lug used
d
45 (1.77)
±5 (±0.2)
e
80 (3.15)
±10 (±0.4)
Connection using a hose
clamp
Length
Tolerance
205 (8.07)
±10 (±0.4)
170 (6.69)
±5 (±0.2)
40 (1.57)
±5 (±0.2)
80 (3.15)
±10 (±0.4)
91