Data Sheets And Diagrams - Siemens SIMOTICS T-1FW6 Configuration Manual

Built-in torque motors for sinamics s120
Hide thumbs Also See for SIMOTICS T-1FW6:
Table of Contents

Advertisement

Short-circuit braking torque
For each frame size and active part length, the short-circuit braking torque M
as characteristic "short-circuit braking torque with respect to speed".
Figure 6-7
6.2

Data sheets and diagrams

Table 6- 1
Color coding of the M-n characteristics in the diagrams
Color
Resulting DC link
voltage U
DC
634 V
600 V
528 V
1FW6 Built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
Short-circuit braking torque speed diagram (example)
Converter output voltage
(rms value) U
a max
460 V
425 V
380 V
Technical data and characteristics
Permissible line supply voltage
(rms value)
3 x AC 480 V
3 x AC 400 V
3 x AC 400 V
6.2 Data sheets and diagrams
is specified
BR
SINAMICS S120
Line Module
Smart Line Module,
uncontrolled with regener-
ative feedback
or
Basic Line Module,
uncontrolled without re-
generative feedback
Active Line Module,
controlled with regenera-
tive feedback
Smart Line Module,
uncontrolled with regener-
ative feedback
or
Basic Line Module,
uncontrolled without re-
generative feedback
163