Installation drawings/Dimension drawings
9.1
Installation situation for motors with a cooling jacket
Design information for installation hole and O ring
● Provide insertion inclines: Minimum length Z at 15°: 3 mm, at 20°: 2 mm, edges rounded
and polished
Debur and round inside holes (cooling water connections)
● Surface quality of the opposite sealing surfaces: R
● Note the installation hole fit (H8). If the play is too great, the O-ring does not provide
sufficient sealing or the permissible gap is too large.
Figure 9-1
9.2
Information on the installation drawings
Note
Please note that certain motors can only be mounted at the A flange as a result of their
design, refer to the Table "Mounting at the A flange" in Chapter "Specifications relating to the
mounting side (Page 125)".
1FW6 Built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE00-0BP9
Design information for installation hole and O ring
≤ 16 µm, R
≤ 10 µm, R
max
z
9
≤ 1.6 µm
a
519