Troubleshooting

1.
Disconnect power and follow Pressure
Relief Procedure, page 11, before
checking or repairing.
Problem
Motor does not run:
(verify sprayer is plugged in,
and power switch is on)
3A7653A
2.
Cause
Easy access door not fully
closed.
Pressure Control Knob is set at
zero pressure.
Electric outlet is not providing
power.
Extension cord is damaged.
Sprayer electric cord is
damaged.
Pump is seized (water is frozen
in pump.)
Motor or control is damaged.
Troubleshooting
Solutions at the beginning of each
problem listed are the most common,
Start at the beginning and continue down
the list to find a solution.
844-241-9499
Verify the Easy Access Door is
closed and latched. See page
23.
Turn Pressure Control Knob
clockwise to increase pressure
setting.
Test outlet with known working
device.
Reset circuit breaker or
replace fuse.
Find working outlet.
Reset building circuit breaker
or replace fuse.
Replace extension cord. See
page 9.
Check for broken insulation or
wires. Replace electric cord if
damaged.
Turn ON/OFF Switch off and
unplug sprayer from outlet.
If frozen do NOT try to start
sprayer until it is completely
thawed or it may damage the
motor, control board and/or
drive train.
Place sprayer in warm area for
several hours. Check for free
moving pump by removing
shroud and spinning fan.
If not frozen, replace pump.
See Parts, page 28.
Replace motor or pump
assembly. See Parts, page 28.
Solution