Maintenance
Maintenance
Routine maintenance is important to ensure proper operation of your sprayer.
Inspect/clean Fluid Inlet strainer.
Inspect motor shroud openings for blockage.
NOTICE
Protect the internal drive parts of this
sprayer from water. Openings in shroud
allow cooling of mechanical parts and
electronics inside. If water gets into these
openings, the sprayer could malfunction or
be permanently damaged.
Airless Hoses
Check Airless Hose for damage every time
you spray. Do not attempt to repair Airless
Hose if hose jacket or fittings are damaged.
Do not use Airless Hoses shorter than 25 ft.
Wrench tighten, using two wrenches.
Spray Tips
•
Always clean tips with water and brush
after spraying.
•
Tips may require replacement after 15
gallons or they may last through 60
gallons.
Pump Repair
When pump packings wear, material will
begin to leak down outside of pump.
Purchase a replacement Pump Assembly.
See Parts, page 28. Install according to
Pump Removal and Pump Installation
instructions, pages 22 and 23.
22
Activity
Daily or each time you spray
Daily or each time you spray
Pump Removal
The Hopper must be removed before pump
can be removed.
Always perform Pressure Relief Procedure,
page 11, before starting any pump repairs.
1.
Pull tabs on sides of the Easy Access
Door pump towards you while pushing
the entire door away from the inlet end of
the pump.
2.
Now lift the door so that it swivels out of
the way.
1
2
3
ti27463a
Interval
3A7653A