Carrier WeatherMaster Puron 48HC D17 Service And Maintenance Instructions page 42

Gas heat/electric cooling with r-410a refrigerant
Table of Contents

Advertisement

NATURAL GAS
ELEVATION
Feet
Meters
0-2000
0-610
2000
610
3000
914
4000
1219
5000
1524
6000
1829
7000
2134
8000
2438
9000
2743
10,000
3048
11,000
3353
12,000
3658
13,000
3962
14,000
4267
* As the height above sea level increases, there is less oxygen per cubic ft. of air. Therefore, heat input rate should be reduced at higher altitudes.
KIT NO.:
XX
1
= CRNGELEV001A00
XX
2
= CRNGELEV002A00
XX
3
= CRLPELEV005A00
XX
4
= CRLPELEV006A00
XX
= CRLPKIT9001A00
5
PROPANE GAS
ELEVATION
Feet
Meters
0-2000
0-610
2000
610
3000
914
4000
1219
5000
1524
6000
1829
7000
2134
8000
2438
9000
2743
10,000
3048
11,000
3353
12,000
3658
13,000
3962
14,000
4267
* As the height above sea level increases, there is less oxygen per cubic ft. of air. Therefore, heat input rate should be reduced at higher altitudes.
KIT NO.:
XX
= CRNGELEV001A00
1
XX
2
= CRNGELEV002A00
XX
3
= CRLPELEV005A00
XX
4
= CRLPELEV006A00
XX
5
= CRLPKIT9001A00
Table 16 — Altitude Compensation* (17-30) for Natural Gas
220k BTUH
Orifice Size
Input (btu/hr)
30
220,000
30
202,400
31
193,600
1
31
184,800
1
31
1
176,000
31
1
167,200
32
1
158,400
32
1
149,600
34
1
140,800
35
132,000
2
37
2
123,200
37
2
114,400
39
2
105,600
39
2
96,800
Table 17 — Altitude Compensation* (17-30) for Propane Gas
220k BTUH
Orifice Size
Input (btu/hr)
48
5
220,000
49
3
202,400
49
3
193,600
49
3
184,800
50
3
176,000
50
167,200
3
50
3
158,400
51
3
149,600
51
3
140,800
52
4
132,000
52
4
123,200
53
114,400
4
53
105,600
4
53
4
96,800
NOMINAL HEAT INPUT
310k BTUH
Orifice Size
Input (btu/hr)
30
310,000
30
285,200
31
272,800
1
31
260,400
1
31
1
248,000
31
1
235,600
32
1
223,200
32
1
210,800
34
1
198,400
35
186,000
2
37
2
173,600
37
2
161,200
39
2
148,800
39
2
136,400
NOMINAL HEAT INPUT
310k BTUH
Orifice Size
Input (btu/hr)
48
5
310,000
49
3
285,200
49
3
272,800
49
3
260,400
50
3
248,000
50
235,600
3
50
3
223,200
51
3
210,800
51
3
198,400
52
4
186,000
52
4
173,600
53
161,200
4
53
148,800
4
53
4
136,400
42
400k BTUH
Orifice Size
Input (btu/hr)
30
400,000
30
368,000
31
352,000
1
31
336,000
1
31
1
320,000
31
1
304,000
32
1
288,000
32
1
272,000
34
1
256,000
35
240,000
2
37
2
224,000
37
2
208,000
39
2
192,000
39
2
176,000
400k BTUH
Orifice Size
Input (btu/hr)
48
5
400,000
49
3
368,000
49
3
352,000
49
3
336,000
50
3
320,000
50
304,000
3
50
3
288,000
51
3
272,000
51
3
256,000
52
4
240,000
52
4
224,000
53
208,000
4
53
192,000
4
53
4
176,000