Initial High Availability Setup 
Before you begin the configuration of HA on the Primary 
SonicWall security appliance, perform the following tasks:
• Determine which interfaces should be used as the HA 
Control Link and the HA Data Link. Remember, they must 
be the same ports on each appliance. 
• Make a note of the serial number of the appliance that will 
run as the Secondary device. You can find this on the 
bottom of the appliance or in the System > Status page. 
You need to enter this number in the High Availability > 
Settings > HA Devices page.
• Verify that the Primary and Secondary appliances are 
registered on MySonicWall and are running the same 
SonicOS versions.
• Ensure that the Primary and Secondary security appliances' 
LAN, WAN, and other interfaces are properly connected for 
failover.
• Connect the HA Control and Data Links on the Primary and 
Secondary appliances with appropriate cables. 
• Turn on the Primary SonicWall security appliance first. 
Then, turn on the Secondary SonicWall security appliance.
42
SonicWall SuperMassive 9200/9400/9600 Getting Started Guide
Configuring High Availability Settings
The first task in setting up HA after completing Initial Setup on 
page 13 is configuring the High Availability > Settings page on 
the Primary SonicWall security appliance. Once you configure 
HA on the Primary appliance, it communicates the settings to 
the Secondary appliance.
To configure HA settings on the Primary appliance: 
1 Log into your Primary appliance as an administrator.
2 Navigate to the High Availability > Settings page. 
3 On the General tab, select Active / Standby from the 
Mode drop‐down list. 
4 Click OK in the popup dialog about license and 
signature updates.
5 Select the Enable Stateful Synchronization checkbox. 
6 Click OK in the popup dialog about the recommended 
settings for Heartbeat Interval and Probe Interval.
7 Click on the HA Devices tab and type in the serial 
number for the Secondary appliance.
8 Click on the HA Interfaces tab and select interfaces for 
HA Control Interface and HA Data Interface. 