Prepare The Site - Kohler K-3900X-2 Installation Manual

Integrated toilet
Hide thumbs Also See for K-3900X-2:

Advertisement

Available languages

Available languages

Supply Stop
76 mm Max
When Located
Behind Toilet

Prepare the Site

WARNING: Risk of electric shock. Disconnect power before installation or servicing.
WARNING: Risk of electric shock. Connect only to a properly-grounded, grounding-type receptacle
which is protected by a 220~240V, 50/60 Hz Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage
Circuit-Breaker (ELCB). Do not remove the grounding pin or use a grounding adapter.
WARNING: Risk of electric shock. For hardwire installations/through-floor electrical supply: Connect
only to a properly-grounded, dedicated circuit protected by an Class A Ground-Fault Circuit-Interrupter
(GFCI) or Earth-Leakage Circuit-Breaker (ELCB).
NOTE: Locating the supply stop behind the toilet will make it difficult to remove the back panel.
Install the Dock Power Cord
If the finished wall has not been installed, embed the in-wall cable conduit to route the docking station power
¨
cord. (concealed type)
If the finished wall is installed, use the slot board cable to route the cord to the docking station location.
¨
(out-loading type)
Install the Water Supply
IMPORTANT! When installing the supply hose, connect it to the toilet first, then the supply stop.
NOTE: The supplied water supply hose is 18" (46 cm) in length. The supplied hose must be used for this
installation.
Install the water supply and supply stop.
¨
Flush the water supply line into a pail or other container to remove all debris.
¨
Install the Electrical Service
NOTE: The suppled power cord is 56" (1420 mm) in length.
Locate a dedicated 220~240 V, 50/60 Hz, 15 A or more grounding-type receptacle, protected by a GFCI or
¨
ELCB, within 142 cm of the back of the toilet.
Install External Speaker Wires (optional)
If external speakers will be used, install the speaker wires at this time with RCA plug installed at line-end
¨
(not presented).
1195109-X2-A
51
203
Dock Power
Cord
GFCI-
Protected
Receptacle
102
6
152
305 mm From
Finished Wall
Recommended,
298 mm Min
Floor Flange
Kohler Co.