Installation
Bosch Rexroth Mellansel AB, Intallation and maintenance manual, Hägglunds VI, RE 15310-WA/10.2015
Fig. 43:
Because they must be run-in, the FK measurement with new brake bands must
be 117 mm (4.61 in). Check the FK measurement after approximately 10 brake
operations and adjust it to 107 mm (4.21 in).
Brake adjustment BA-85
Fig. 44: Double acting, sign 2
Min. 15 mm
(0.59 in)
WARNING
Without braking torque
FK min = 93 mm (3.67 in)
FK max = 107 mm (4.22 in)
Without load
With braking torque
see I&M manual
Warning! FK must
always be more than
With load
m
60 mm (2.37 in)
White field
Green field
Red field
FK definition valid
for both cylinders