Midas PRO6 Owner's Manual page 388

Live audio system
Hide thumbs Also See for PRO6:
Table of Contents

Advertisement

362
Error Message
b
bad device
bad device ID
bad directory
bad file
bad file artefact
bad file version
bad path
bad point scene
ID
System(s)
Problem
File and
Operation could not be
Automation
carried out because the
device, that is, the internal
compact flash of the PRO6 or
USB memory stick (if
connected), does not contain
the required directory
structure.
File and
The device identifier has not
Automation
been recognised.
File and
The file system path does not
Automation
terminate in a directory.
File and
The file system path does not
Automation
terminate in a file.
File and
The file has been detected as
Automation
not valid. Preferences, preset
library and show files are
validated by comparing their
actual attributes against the
corresponding fields stored in
the header of the file, such
as, file size, checksum etc.
File and
The preferences, preset
Automation
library or show file could not
be opened because its file
header version field was not
valid.
File and
A file or directory is missing.
Automation
File and
The scene's point scene ID
Automation
cannot be found.
Appendix G: Troubleshooting
Solution
• If the device is the internal
compact flash of the PRO6,
this could be an indication of
a serious problem. Contact
Midas Technical Support.
• If the device is the USB
memory stick, check that the
device has not been
disconnected from the control
surface.
If you are exporting a file to a
USB memory stick, check
that it has not been
disconnected from the control
surface.
This is highly unlikely to occur
in practice, but is an
indication of a serious error.
Contact Midas Technical
Support.
This is highly unlikely to occur
in practice, but is an
indication of a serious error.
Contact Midas Technical
Support.
Try again.
If still unsuccessful, and if the
file is a show file, try a
backup file, if one is
available.
Try again.
If still unsuccessful, and if the
file is a show file, try a
backup file, if one is
available.
This is an indication of a
serious error. Contact Midas
Technical Support.
Try again.
PRO6 Live Audio System
Owner's Manual

Advertisement

Table of Contents
loading