182 Waveform is too long for the available channel memory
184 Sum or modulation conflict
186 Inter channel lock not possible. Lock status is off.
This error may occur for several reasons. In each case there is a conflict of the
synchronization settings. In most cases the status of the synchronization is set to off.
Any of the following conditions will cause this error:
1. More than one master channel is enabled.
2. No master channel is enabled.
3. The locked channels contain a mixture of DDS and PLL generated waveforms.
4. Frequency tracking is enabled (mode: master/freq) but the frequencies are not
the same on all channels. If clock synthesized waveforms are locked the mode will
be forced to frequency tracking.
5. A synchronized channel is not set to continuous mode.
6. An attempt is made to turn on synchronization with a frequency set too high.
7. An attempt is made to set the frequency too high during synchronization. This
error does not set synchronization to off, the system simply inhibits the setting of the
incorrect frequency.
187 External clock independent channel is illegal with synchronization.
188 Maximum trigger level is +5.0 V
189 Minimum trigger level is –5.0 V
192 Unable to open memory card - try reinserting.
193 Memory card is wrong format or is not formatted
194 Memory card is full. Cannot create WAVES or SETUP directory
195 Sequence segment number out of range min 1, max 1024
196 System clock frequency out of range.
197 File <filename> not found load sts <waveform>
198 Memory card is full. Cannot create Set-up or Waveform file
199 Cannot format memory card. It must have 512 bytes per sector
200 Remove signal from external reference clock before editing reference clock
Remote Warnings
72 Length is different to that in the ARBDEF(CSV) command
Remote Errors
120 Waveform limit value out of range
126 Illegal store number requested
143 External clock not possible for current waveform
146 Remote command is illegal with external clock
162 Byte value outside the range 0 to 255
163 Specified arb name does not exist
164 Command illegal in sweep or tone mode
165 Cannot set waveform frequency or period for a sequence
166 Cannot set sample frequency or period for std waveforms
167 dBm output units assume a 50 Ohm termination
168 Specified units illegal for the selected waveform
169 Command not available for RS232
170 Length value error in binary block
171 Illegal value in arbitrary data
173 Illegal tone number
174 Illegal sequence segment number
175 Cannot insert arb into itself
176 Pattern value is illegal or pattern too long
177 Illegal remote calibration command.
185 Command not available while sweeping.