291, 292, 294
Users Manual
Error Messages
101 Frequency out of range for the selected waveform
102 Sample clock frequency required exceeds 100 MHz
103 Sample clock frequency required is less than 0.1 Hz
104 Pulse/pulse-train period out of range for current set-up
105 Pulse width cannot be greater than the period
106 Absolute value of pulse delay must be < period
107 Pulse width cannot be less than 10 ns
108 Maximum output level exceeded
109 Minimum output level exceeded
110 Minimum dc offset value exceeded
111 Maximum dc offset value exceeded
112 The value entered is out of range
115 There are no arb waveforms defined. Use WAVEFORM CREATE
117 Arb name exists, names must be unique
118 Arb waveform length exceeds available memory
119 Arb waveform length cannot be less than eight points
121 Start address error: must be in the range 0 <= n <= stop addr
122 Stop address error: must be in the range start <= n <= waveform length
125 No GPIB available
126 File has no legal set-up for this instrument
127 System ram error battery fault or firmware updated
128 Point value error: must be in the range -2048 <= n <= +2047
129 Wave offset error: must be in the range -4096 <= n <= +4095
131 Wave amplitude error must be in the range 0 <= n <= 100
132 Block dest error: must be in the range 0 <= n <= waveform length
133 Sequence count value exceeds the maximum of 32,768
134 Sequence count value cannot be less than 1
135 Trigger generator maximum period is 200 s
136 Trigger generator minimum period is 10 µs
137 Waveform is not available with ext clock
138 Burst count value exceeds the maximum of 1,048,575
139 Burst count value cannot be less than 1
140 Trig/Gate freq too high. Max=2.5 MHz. Continuous mode set
141 Selected function is illegal in tone mode TONE MODE CANCELLED!
144 Selected combination of function and mode is illegal
145 Locked master/slave is available with continuous mode only
147 Current set-up requires an arb waveform which does not exist
148 Trig/gate mode and seq step value cause a trigger conflict
149 Seq step value can't mix edge and level between segments
150 Number of pulses in train must be between 1 and 10
151 Pulse train base level must be >-5.0 V and <+5.0 V
152 Pulse level must be >-5.0 V and <+5.0 V
153 Pulse number must be between 1 and 10
154 Sweep frequency values must be 1 mHz to 40 MHz
155 Sweep start freq must be less than stop freq
156 Sweep stop freq must be greater than start freq
157 Sweep time value is out of range 0.001 s < n < 999 s
158 Sweep marker value is out of range 0.001 Hz < n < 40 MHz
160 Not locked. This error indicates that a phase locking operation has failed.
161 Illegal phase value
178 Sum ratio is not possible within level constraints
179 Sum and internal modulation cannot be active together
180 Modulation depth or SCM level is out of range
B-2