SITRANS F US SONOFLO

Tools etc.

Tools for installing trans-
ducer holders on steel pipe
Tools for installing trans-
ducer holders on concrete
pipe

3. Construction of the sensor

Length of angle iron to be used as a ruler having a length approximately corresponding to the
outer diameter of the pipe
Measuring tape
Scriber, pencil or the like
Pocket calculator
Calipers
Sliding gauge
Hammer
Centre punch
Spirit level
Roll of adhesive tape
• Flame cutter or drill with ø 60 mm drill bit for making holes in steel pipes
• Electric or TIG welder for welding the mounting plate and the transducer holder
Special drill unit for drilling ø 46 mm holes in concrete
Filler
A suitable filler or mortar does not shrink when setting. A comparatively short setting time is
preferred.
SFIDK.PS.029.V3.02 - 521H0553