Maintenance

Note: Determine the left and right sides of the machine from the normal operating position.

Recommended Maintenance Schedule(s)

Maintenance Service
Interval
After the first 100 hours
After the first 250 hours
Before each use or daily
Every 50 hours
Every 250 hours
Every 300 hours
Every 500 hours
Every 800 hours
Maintenance Procedure
• Check the stakedown planetary-drive oil level (Also, check if external leakage
is observed).
• Check the rotary motor planetary-drive oil level (Also, check if external leakage
is observed).
• Check the thrust motor planetary-drive oil.
• Check the gearbox drive oil.
• Change the gearbox-drive oil.
• Adjust the valve clearance.
• Change the planetary-drive oil.
• Check the fuel level.
• Grease the machine. (Grease immediately after every washing).
• Check the crankcase-vent tube and clean it if necessary.
• Check the indicator on the display screen for a restricted air filter.
• Check the engine oil level.
• Check the track tension.
• Check the coolant level in the radiator.
• Check the hydraulic fluid level.
• Check the drilling-fluid pump oil level.
• Clean the machine with the spray-hose attachment.
• Check and clean the dust valve.
• Remove air cleaner cover and clean out debris. Do not remove the filter.
• Check the fuel-water separator for water and sediment.
• Check the battery condition.
• Check the tracks rotary motor planetary-drive oil level (Also, check if external
leakage is observed).
• Clean or replace the air-cleaner filter.
• Change the engine oil filter.
• Change the engine oil.
• Replace the primary and secondary fuel filters.
• Check the condition of the engine-drive belt.
• Check the condition of the coolant system components. Clean dirt and debris from
them and repair or replace the components as necessary.
• Inspect the fuel lines and connections.
• Check the stakedown planetary-drive oil level (Also, check if external leakage
is observed).
• Check the rotary motor planetary-drive oil level (Also, check if external leakage
is observed).
• Check the thrust motor planetary-drive oil (or yearly, whichever comes first).
• Check the gearbox drive oil (or yearly, whichever comes first).
• Change the gearbox-drive oil (or yearly, whichever comes first).
• Change the hydrostatic-charge filter.
• Change the drilling-fluid pump oil.
• Change the planetary-drive oil (or yearly, whichever comes first).