Cooling System Maintenance - Toro 4045 Operator's Manual

Directional drill
Table of Contents

Advertisement

Loosening the Track Tension
If the track seems tight, loosen the track tension as follows:
1. Park the machine on a level surface, stop the engine,
and remove the ignition key.
2. Remove dirt and debris found around the track-tension
grease valve
(Figure
Important: Ensure that the entire area
surrounding the track-tension grease valve is clean
before beginning to adjust the track tension.
3. Remove the retaining bolts and the cover that house
the track-tension grease valve.
4. Turn the track-tension grease valve counterclockwise
no more than 1 revolution
Note: A 1-revolution turn will release grease and
loosen the track.
5. When the tension reaches 31,026 kPa (4,500 psi), turn
the track-tension grease valve clockwise to tighten it.
6. Remove excess grease from around the valve.
7. Install the cover and retaining bolts.
8. Repeat steps
2
through
the other side.
139).
(Figure
139).
7
to loosen the track tension on
Cooling System
Maintenance
Coolant specification: 50/50 solution of ethylene-glycol
antifreeze and water or equivalent
Engine and Radiator coolant capacity: 16.8 L (17.7 US qt)
WARNING
If you remove the radiator cap from a hot engine,
hot coolant could spray, causing scalding.
• Wear face protection when opening the radiator
cap.
• Allow the cooling system to cool down to below
50°C (120°F) before removing the radiator cap.
• Follow the instructions for checking and
maintaining the engine cooling system.
WARNING
Coolant is toxic.
• Keep coolant away from children and pets.
• If you are not using the same coolant again,
dispose of it according to local environmental
regulations.
100