Main
Sub
code
code
66
02
FAX soft SW initializing
Used to clear the FAX-related soft SW values except for the line signal adjustment value and the machine
adjustment value and set them to the default values (which differ depending on the country code).
Sim66-2 SOFT SW
COUNTRY CODE
Japan
1/34 SELECT UP DN
Sim66-2 SOFT SW
INITIAL
ARE YOU SURE? EXEC
03
FAX PWB memory check
Used to check read/write from/into the memory on the FAX PWB. The check result is displayed for each
memory.
Sim66-3
1:DRAM
2:SRAM
3:ROM
( 1 - 6 )
Sim66-3
DRAM
Sim66-3
DRAM
CHECKING MEMORY
*Interruption with [C] key
during execution cannot be made.
Sim66-2 SOFT SW
COUNTRY CODE
00000000
Sweden
25/34 SELECT UP DN
Input of a value cannot be made.
[OK] key
Sim66-2 SOFT SW
INITIAL
[OK] key
Selection
U.S.A.
10110101
Thailand
10101001
U.K.
10110100
Middle east
11111101
Germany
00000100
India
01010011
France
00111101
Sweden
10100101
Australia
00001001
New Zealand 01111110
China
00100110
Spain
10100000
Singapore
10011100
Portugal
10001011
Malaysia
01101100
Italy
01011001
Hong Kong
01010000
Switzerland
10100110
Taiwan
11111110
Finland
00111100
[CA] key
[INTERRUPT] key : Sub code input window
Numeric keys
MEMOR CHK
[OK] key
4:IMAGE
[START] key
5:PAGE
[BACK] key
6:MODEM
[C] key
X
Execution error end
[OK] key
(Highlighted during execution)
Sim66-3
MEMOR CHK
DRAM
MEMORY CHECK RESULT
NG XXXXXXXX SUM
EXEC
[OK] key
Execution normal end
(Highlighted during execution)
MEMOR CHK
Sim66-3
DRAM
MEMORY CHECK RESULT
OK
EXEC
MX-M182 SIMULATIONS 7-52
Contents
[CA] key
[INTERRUPT] key : Sub code input window
[OK] key
100101
[START] key
[C] key
[BACK] key
Sim66-2 SOFT SW
INITIALIZED
Completion
EXEC
of execution
(Highlighted
during execution)
Simulation code input window
Denmark
00110001
Pohland
Norway
10000010
Russia
Netherlands
01111011
Brazil
Luxembourg
01101001
Belgium
00001111
South Africa
10011111
Czech
00101110
Slovakia
11111100
Hungary
01010001
Greece
01000110
: Simulation cancel
: Item selection
: Settlement and execution of the input value
: Settlement of the input value
: Returns to the selection window.
: Disable
MEMOR CHK
[BACK] key
NG XXXXXXXX SUM
NG XXXXXXXX A-BUS
NG XXXXXXXX DATA
NG XXXXXXXX D-BUS
NG XXXXXXXX ERASE
NG XXXXXXXX IO
MEMOR CHK
[BACK] key
SIM66-3 initial window
: Simulation cancel
: Settlement
: Settlement
: Disable
: Disable
1sec later
10001010
10111000
00010110
Remark