Download Print this page

Sharp MX-M182 Service Manual page 60

Digital multifunctional system
Hide thumbs Also See for MX-M182:

Advertisement

Main
Sub
code
code
26
42
Transfer ON/OFF timing control setting
Used to set the ON/OF timing of the transfer charger (TC) individually. Select an item to be changed with the
arrow keys, and change the set value to a desired value, and press [OK] key or [START] key. The entered
value is saved to the EEPROM and the machine shifts to the sub code input window.
(Item selection)
Sim26-42 TC TIMING
1:TC(ON)
2:TC(OFF)
[
1- 99]
Key,
Variation in the adjustment value
•18cpm/20cpm machine
Set value
99
• • •
50
• • •
38
• • •
1
•23cpm machine
Set value
99
• • •
50
• • •
38
• • •
1
*
Setting range is 1 - 99.
In the case of 88mm/s, when the set value is increased by 1, the timing is increased by 2ms.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
43
Side void amount setting
Used to set the left and right side void amounts. The left side void amount and the right side void amount
can be set individually. Select an item to be changed with the arrow keys and change the set value to a
desired value. The setting range is 0-10. When the value is increased by 1, the void amount is increased by
0.5mm. The default is 5 (= 2.5mm).
(Item selection)
Sim26-43 SIDE VOID
1:SIDE VOID(L)
2:SIDE VOID(R)
[
0- 10]
Key,
Display: Set item
1:SIDE BOID(L) : Left side void amount setting
2:SIDE VOID(R) : Right side void amount setting
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
(Value input)
Sim26-42 TC TIMING
1:TC(ON)
38
50
2:TC(OFF)
50
Key
Numeric Key
1:TC(ON)
PS release
TC ON
Time (ms)
Difference (ms)
442
+122
• • •
• • •
344
+24
• • •
• • •
320
0
• • •
• • •
246
-74
1:TC(ON)
PS release
TC ON
Time (ms)
Difference (ms)
367
101
• • •
• • •
286
20
• • •
• • •
266
0
• • •
• • •
204
-62
(Value input)
Sim26-43 SIDE VOID
1:SIDE VOID(L)
3
2:SIDE VOID(R)
3
3
Key
Numeric Key
MX-M182 SIMULATIONS 7-24
Contents
(Settlement)
38
50
[
1- 99]
60
2
2:TC(OFF)
PIN OFF
Set value
Time (ms)
99
402
• • •
• • •
51
306
50
304
49
302
• • •
• • •
1
206
2:TC(OFF)
PIN OFF
Set value
Time (ms)
99
334
• • •
• • •
51
254
50
252
49
251
• • •
• • •
1
171
(Settlement)
3
3
[
0- 10]
4
2
Default:
38 (TC ON)
50 (TC OFF)
Sim26-42 TC TIMING
1:TC(ON)
60
2:TC(OFF)
50
[
1- 99]
60
[OK] key or [START] Key
TC OFF
Difference (ms)
+98
• • •
+2
0
-2
• • •
-98
TC OFF
Difference (ms)
82
• • •
2
0
-1
• • •
-81
Default:
5 (Void amount:
2.5mm)
Sim26-43 SIDE VOID
1:SIDE VOID(L)
4
2:SIDE VOID(R)
3
[
0- 10]
4
[OK] key or [START] Key
Remark

Advertisement

loading

This manual is also suitable for:

Mx-m182dMx-m202dMx-m232d