code
H5
01
Content
5 continuous POUT not-reached error
Detail
When 5 continuous not-reached jams to the
paper exit sensor (POUT) occur.
The jam counter is backed up and it is used in
a job after turning on the power.
Cause
Jam paper is not removed from the fusing unit.
(Jam paper remains.)
Paper exit sensor breakdown or harness
connection trouble
Fusing unit installation trouble
Check
Check for jam paper remaining in the fusing
and
unit. (winding, etc.)
remedy
Check the POUT sensor harness, and check
installation of the fusing unit.
Use SIM14 to clear the self diag display.
L1
00
Content
Scanner feed trouble
Detail
Though the specified steps of motor pulses are
outputted, the mirror home position sensor
remains ON.
Cause
Mirror unit abnormality
The scanner wire is disconnected.
The origin detection sensor abnormality
Mirror motor harness abnormality
Check
Use SIM 1-1 to check the mirror reciprocating
and
operations.
remedy
When the mirror does not feed.
Check for disconnection of the scanner wire.
Check the harness and the connector between
the mirror motor and the MCU PWB.
Replace the mirror unit.
Replace the MCU PWB.
When the mirror does feed.
Use SIM 1-2 to check the mirror home position
sensor.
L3
00
Content
Scanner return trouble
Detail
Though the specified steps of motor pulses are
outputted, the mirror home position sensor
does not turn ON.
Cause
Mirror unit abnormality
Scanner wire disconnection
Origin detection sensor abnormality
Mirror motor harness abnormality
Check
Use SIM 1-1 to check the mirror reciprocating
and
operations.
remedy
When the mirror does not return.
Check for disconnection of the scanner wire.
Check the harness and the connector between
the mirror motor and the MCU PWB.
Replace the mirror unit.
Replace the MCU PWB.
When the mirror does feed.
Use SIM 1-2 to check the mirror home position
sensor.
Details of trouble
MX-M182 TROUBLE CODE LIST 8-5
Main
Sub
code
code
L4
01
Content
Main motor lock detection
Detail
The main motor does not rotate.
After rotation of the main motor, the motor lock
signal is detected for 1 sec or more.
During rotation of the main motor, the motor
lock signal is detected for 1 sec.
When the main motor is stopped, the motor
lock signal is not detected for 5sec or more.
(Though the motor is stationary, it is judged as
stable rotation.)
Cause
Main motor unit abnormality
Improper connection or disconnection the main
motor and the harness.
MCU PWB abnormality
Check
Use SIM 25-01 to check the main motor
and
operations.
remedy
Check connection of the main motor harness/
connector.
Replace the main motor.
Replace the MCU PWB.
11
Content
Shifter motor trouble.
Detail
The shifter home position detection signal is
not detected when initializing the shifter.
Cause
Shifter motor abnormality, improper connection
or disconnection of the harness, shifter home
position sensor abnormality.
Check
Use SIM 03-11 to check the shifter motor
and
operations.
remedy
Check connection of the harness/connector of
the shifter motor.
Replace the shifter motor.
Replace the MCU PWB.
32
Content
PSFAN lock detection
Detail
The PSFAN does not rotate.
Sampling is performed in 50msec interval, and
the normal signal cannot be detected 5 times
continuously in 1 sec.
Cause
Fan trouble or harness contact trouble and
disconnection
Check
Check connection of the fan harness and the
and
connector.
remedy
Replace the fan.
Replace the MCU PWB.
L6
10
Content
Polygon motor lock detection
Detail
The polygon motor does not rotate
After beginning to rotate the polygon motor, the
motor lock signal is detected for 20sec or more.
During rotation of the polygon motor, the motor
lock signal is detected for 1sec.
Cause
Polygon motor unit abnormality
Improper connection or disconnection of the
polygon motor and the harness.
MCU PWB abnormality
Check
Use SIM 61-3 to check the polygon motor
and
operations.
remedy
Check connection of the polygon motor
harness/connector.
Replace the LSU unit.
Replace the MCU PWB.