Download Print this page

Sharp MX-M182 Service Manual page 65

Digital multifunctional system
Hide thumbs Also See for MX-M182:

Advertisement

Main
Sub
code
code
43
02
Fusing temperature setting 2
When this simulation is executed, the current set value is displayed.
Every time when [ ] key is pressed, the current display value is increased. For the set value, refer to Table 1.
Every time when [ ] key is pressed, the current display value is decreased. For the set value, refer to Table 1.
Enter a desired set value (temperature), and press [OK] key or [START] key. The set value is caved in the
EEPROM.
Sim43-2 FUSER TMP 2
1:SUSPEND
2:RESUME
3:COOLDOWN
Window display
1: SUSPEND
2: RESUME
3: COOLDOWN
*1, *2: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 1.)
Table 1:
NO.
Temperature (°C) 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
03
Fusing temperature setting 3
When this simulation is executed, the current set value is displayed.
Every time when [ ] key is pressed, the current display value is increased. For the set value, refer to Table 1
and 2.
Every time when [ ] key is pressed, the current display value is decreased. For the set value, refer to
Table 1 and 2.
Enter a desired set value (temperature), and press [OK] key or [START] key. The set value is caved in the
EEPROM.
Sim43-3 FUSER TMP 3
1:PREHEAT
2:WARMUP1
3:WARMUP2
Window display
1: PREHEAT
2: WARMUP1
3: WARMUP2
*1: When the set value is increased by 1, the target temperature is increased by 10°C. (Refer to Table 2.)
*2: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 1.)
*3: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 1.)
Table 1:
NO.
Temperature (°C) 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230
Table 2:
NO.
Temperature (°C) 80
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
Contents
230
180
0
230
Setting item
Sub thermistor temperature when shifting to high temperature alarm
Sub thermistor temperature when canceling high temperature alarm
Main motor rotation time (sec) after completion of a JOB
0
1
2
3
4
5
110
100
150
110
Setting item
Main thermistor target temperature during preliminary heating
When the initial temperature is below 120°C during warm-up
Main thermistor target temperature
When the initial temperature is above 120°C during warm-up
Main thermistor target temperature
0
1
2
3
4
5
0
1
2
3
4
5
90 100 110 120 130 140 150 160
MX-M182 SIMULATIONS 7-29
6
7
8
9
10
11
12
6
7
8
9
10
11
12
6
7
8
Remark
Setting range
Default:
150 - 230 *1
SUSPEND: 230
150 - 230 *2
RESUME: 180
0 - 90
COOLDOWN: 0
13
14
15
16
Setting range
Default:
80 - 160 *1
PREHEAT: 110
150 - 230 *2
WARMUP1: 160
WARMUP2: 150
150 - 230 *3
13
14
15
16

Advertisement