Error Responses
If the switcher is unable to execute a command it receives because the command is invalid
or contains invalid parameters, the switcher returns an error response to the host. The
following error response codes can be sent:
E01 – Invalid input channel (out of range)
E06 – Invalid input during auto-input switching
E10 – Invalid command
E13 – Invalid value (out of range)
Using the Command and Response Table
The
valid ASCII and hexadecimal command codes, the switcher responses to the host, and a
description of the command function or the results of executing the command.
The conversion table below is for use with the command and response table.
Space
Figure 13.
Symbol Definitions
]
}
•
= Space
E
X!
X@
X#
X%
X^
X&
Command and Response Table for SIS
ASCII to Hex Conversion Table
ASCII to Hex Conversion Table
= CR/LF (carriage return with line feed) (hex
|
or
= Soft carriage return (no line feed)
W
or
= Escape
=
Input number
0
through the maximum number of inputs on the unit
0
= Deselect (mute) all inputs
For auto‑input switching:
1 through maximum number of inputs available.
=
On and off, or audio mute status
0
= Off or unmuted
1
= On or muted
=
Video color bit depth mode
0
= Automatically truncate based on output (default)
1
= Force truncation to 8-bit
=
Current EDID information in hexadecimal format (128 or 256 bytes of hex data)
=
Native resolution and refresh rate
=
Unit name. The name can have up to 24 alphanumeric characters including hyphens (
with no spaces. The first character must be a letter, and the last character cannot be a
SW-HD-4K-SERIES
hyphen. The default is
SW HD 4K PLUS Series • Remote Configuration and Control
Commands, starting on page 23, lists
•
0D 0A
)
.
-
),