Figure 37 . Attach Blower to
the stove bottom and connect
wires to Snapstat.
4. Attach the Blower directly to the tapped hole in the
cast iron stove bottom using the two M6 x 12 mm
flange head hex bolts.
5. Attach either Snapstat wire connector to either Snap-
stat terminal. See figs.35 and 37.
6. Connect power cord to the nearest outlet.
Blower Operation
The variable-speed blower will enhance heat circulation
around the firebox and out into the room. The blower is
controlled by a heat activated switch (snapstat) that will
function only when the control switch is in the AUTO
setting. After the fire has been burning for a time, the
snapstat will react to the heat and activate the blower.
Fan speed may be manually adjusted with the rheostat
knob. If the burner turns off, the blower will be shut off
automatically when the stove cools down.
If automatic blower circulation is not desired, place
the blower control switch in the MANUAL position. That
will override the snapstat allowing the blower to run
continuously.
Snapstat
Connectors
Mounting Bracket
for GF100 DV II MV
#8 x 1/2" sheet
M6 x 12 mm
Hex Bolts
G
W
W
G
BL
BK
POWER
SNAPSTAT
SUPPLY
GY
BL
MANUAL OFF AUTO
AUTO OFF
Figure 38. Blower Wiring Diagram
CAUTION:
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IM-
PROPER AND DANGEROUS OPERATION.
VERIFY OPERATION AFTER SERVICING.
ATTENTION:
AU MOMENT DE L'ENTRENTIEN DES COMMANDES,
ETIQUIETEZ TOUS LE FILS AVANT LE DEBRANCHEMENT.
ES ERREURS DE CEBLAGE PEUVENT ENTRA TUN FONC-
TIONNEMENT INADEQUAT ET DANGEREUX.
139955-01_ GF 200 DVII MV / Sept. 2019
metal screws
BLOWER
BK
W
BK
RHEOSTAT
BK
SWITCH
MANUAL
25