FAULT CODES and OPERATIONS

CODE
F1
Meat probe failure during test or service mode
F2
Oven sensor failure during test or service mode
F3
Warming drawer sensor failure during test or service mode
F31
Oven temperature sensor failure
F32
Oven sensor shorted
F33
Warming drawer sensor failure
F34
Drawer sensor shorted
F41
Motorized latch will not lock
F43
Motorized latch will not unlock
F45
Motorized latch both locked and unlocked
F111
Runaway oven temperature 585
F113
Runaway oven temperature 950
F120
Any key (except Cancel) pressed only than 60 sec.
F121
Touch key voltage out of limits (except cancel key
F122
Selection mechanism for touch keys faulty
F124
Cancel key pressed for more than 60 sec.
F125
Cancel touch key voltage out of limits
F131
Probe not calibrated
F132
Shorted meat probe input
DESCRIPTION
o
F
o
F
Jan. 2008, Iss. 1
WHEN CHECKED
Only during test or service
Only during test or service
Only during test or service
Cook or clean programmed
When Cook/Clean active
When warming drawer is active
During cook/warming drawer is active
Latch should be locked
Latch should be unlocked
Always
Latch unlocked
Latch locked
Always
Always
Always
Always
Always
When probe in program
When probe in program
FAULT LIMIT
None
None
None
20 Sec*
20 Sec.
20 Sec.*
20 Sec.
1 Min.
5 Sec.
1 Min.
5 Sec.
5 Sec.
1 Min.
Max. 1 Min.
Max. 1 Min.
Max. 1 Min.
1 Min.
20 Sec.
1 Min.
72