Multi Variable Air Conditioners Indoor Unit for North America

4.4 Console Type Indoor Unit

Step
1. Open the panel
2.Remove filter
and front case
3. Remove
electric box
4. Remove water
tray and swing
motor
5. Remove
evaporator
Removal of Fan Motor
Remark: before removing, making sure power is disconnected.
Diagram
●Press clasps at both sides to
―OPEN‖ position.
●Remove 5 screws fixing the front
case.
●Open electric box cover, loosen all
connection wires and then remove
screws.
●Remove 2 screws fixing water tray
and swing motor respectively.
●Remove the fixer fixing the
evaporator, press 2 clasps at left
side and then remove the
evaporator.